Troubleshooting

Nova SIT 820 Standing Pilot

START

Gas Supply On

YES

Pilot Lights with

Piezo Ignitor

YES

Pilot Stays Lit

YES

Pilot Lights Main

Burner

YES

 

 

CHECK

NO

 

Supply Line Hooked up

 

 

 

Shutoff Valve Open

Lockout has engaged. Wait 60 seconds and try again.

Piezo not tight enough for good ground.

NO For spark at electrode while depressing Piezo (Red Button) 1/8" gap to pilot hood needed.

All wiring connections Replace Piezo Ignitor Thermodisk

For Air in the lines Thermopile needs a minimum

325mV. Adjust pilot flame height. All wiring connections

NO Replace Thermopile Thermocouple needs a minimum

of 14mV.

Defective valve. Turn to pilot, meter should read greater than 100mV.

Thermodisk

Wall switch is not turned on. Watch for grounded wires!

NO Thermopile needs a minimum 325mV

Plugged burner orifice Doors not fully open (Fig. 10)

System OK