Pre-Installation Checklist

Pre-Installation Checklist

Yes No

Are you burning Natural Gas? If you have Propane Gas, you need to purchase a factory authorized safety pilot kit (see below).

Is the gas supply inlet pressure correct?NG: Min. 3.5” w.c./Max. 7.0” w.c.

Does the firebox meet the minimum size dimensions below?

Is your fireplace plumbed with gas on the right side (facing) of the fireplace?

If not, see Page 4.

Is the gas supply line sized properly (Minimum 1/2” iron pipe)?

Do you have a solid fuel (wood burning) fireplace with a vented flue?

Do you have a manual gas supply valve installed at your fireplace? If not, a licensed plumber, gas company technician or other qualified installer must install one.

Have you checked local building codes? (Check with your local building department)

Does your fireplace have a wire mesh screen in place?

CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance.

Minimum Clearances & Specifications

Natural Gas Units

 

 

 

Minimum Firebox Dimensions

Minimum

Gas Fuel Line

Set

Input

Width

 

 

Flue

Pressure

Size

Btu/hr

Back

Front

Depth

Height

Size

Minimum

Maximum

18”

54,000

16”

24”

15”

18”

51 sq.in.

3.5” w.c.

7.0” w.c.

24”

90,000

20”

30”

15”

18”

79 sq.in.

3.5” w.c.

7.0” w.c.

30”

90,000

27”

36”

18”

18”

79 sq.in.

3.5” w.c.

7.0” w.c.

NOTE: Use of a Pilot or LP Conversion Kit will add 3” to the minimum width requirements. Refer to the pilot kit’s installation instructions.

Propane (LP) Conversion

USE OF THIS SET WITH LP OR PROPANE FUEL REQUIRES THE INSTALLATION OF ONE OF OUR FACTORY AUTHORIZED SAFETY PILOT KITS:

MODEL SPK P - Pilot Kit with Piezo Spark Ignition

MODEL RVKRP - Millivolt Pilot Kit with Remote Control Capabilities