Figure 5b | CFM159 |
|
Figure 5c | CFM150 |
Leak Test Procedures
Create a mixture of equal parts soap and water. Apply to all the joints of the pipe fittings from the gas supply pipe to the burner. Turn on the gas supply valve for no longer than
WARNING: Do not use an open flame to test for leaks!
NOTE: Always perform a leak test any time the appliance has been moved or disconnected from the gas supply line.
Adding Pan Material
1.Open the bag of Silica Sand and spread it evenly across the Burner Pan, to the top, as shown in Figure 6. You may overflow the front and sides of the pan to cover the entire pan and connecting hardware. NOTE: Sand is for use with Natural Gas ONLY! Vermiculite or Lava Rock must be used in place of Sand for Propane Gas. See Propane Conversion Kit Manual for details.
2.Next, open the bag of Glowing Embers and place them on top of the Silica Sand, evenly across the Burner Pan. Be sure to separate the Glowing Embers into very small pieces before placing them onto the Silica Sand.
20003889
| Glowing |
| Embers |
| Silica |
| Sand |
| Glowing |
| Embers |
| Lava Rock |
Figure 6 | LG370 |
| 7 |