Vermont Casting SR24SHK manual For Your Safety Read Before Lighting, What To Do If You Smell Gas

Models: SR24SHK SR30SHK SR18SHK

1 16
Download 16 pages 55.57 Kb
Page 9
Image 9
FOR YOUR SAFETY READ BEFORE LIGHTING

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these directions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electrical switch, do not use any phone in your building

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department

Lighting Instructions

1.Turn the gas shut-off valve to OFF.

2.Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow the safety information on above. If you do not smell gas, go on to the next step.

3.Light a match and lay it on top of the pan material, about 2” from the end of the supply side of the pan. (Fig. 8)

4.Slowly turn the gas shut-off valve ON until the burner ignites. If the burner does not ignite within ten (10) seconds with the match burning, turn the shut-off valve OFF and repeat steps 1 through 4 again.

Figure 9

LG176

Match

WARNING: Flame may flare up when ignited. Keep hands and face away from firebox.

Operation and Maintenance

To Adjust the Flame:

Adjust the flame to the desired level by rotating the gas

valve counterclockwise WHAT TO DO IF YOU SMELL GAS to open or clockwise Lighting Instructions to close.

To Turn the Appliance OFF:

Rotate the gas shut-off valve clockwise Operation and Maintenance to OFF.

Proper Maintenance:

Keep the area around the log set clean and clear of debris.

Occasionally, you may use a soft bristle brush to clean logs.

Once every year, a qualified agency or certified chim- ney sweep should examine and clean the venting system of the fireplace in which the log set is installed.

Appliance Break-In

During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various water- based paints used in the manufacture of this log set cure. This is a normal and temporary situation that is not a cause for alarm. However, you may want to provide extra ventilation to the room during this time.

To ensure proper curing of the logs:

1.Ignite a 2” flame and maintain it for 1/2 hour.

2.Burn the logs in consecutive 1/2 hour periods, raising the flame an additional 2” to full flame height for a total of three hours.

3311956

9

Page 9
Image 9
Vermont Casting SR24SHK For Your Safety Read Before Lighting, What To Do If You Smell Gas, Lighting Instructions, 3311956