Majestic Fireplaces® SR/SC Series
Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer.
Installing the Firestop Spacer
in the Ceiling Hole
A firestop spacer is used to keep pipe spaced properly and required for safety.
Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. Note: A firestop spacer is not required at the roof.
Hole sizes listed in Figure 13 for angled firestop spacers provide minimum required air space to chim- ney pipe for ceiling thickness up to eight (8) inches. When combined thickness of ceiling material, ceiling joists and flooring material exceeds eight (8) inches, adjustments must be made in framing to assure that minimum air spaces to chimney are maintained.
PIPE SECTION
PIPE RIM
HEM
LANCE
PIPE
RIM
FP558
Fig. 16 Install pipe, listening for the
Proper Firestop Spacer Installation | SUPPORT |
| ||
Figure 18 shows different installation procedures for |
| |||
STRUCTURE |
| |||
both an area that is an attic and an area that is not an |
|
| ||
attic. |
| ELBOW |
| |
If the area above the ceiling is not an attic, position the |
| |||
STRAP | CEILING | |||
firestop spacer with the flange on the ceiling side and | ||||
(must be tight) | HOLE | |||
the angled portion extending up into the hole. |
| FRAMING | ||
If the area above the ceiling is an attic, position the | ELBOW STRAP |
| ||
firestop spacer with the flange on the top of the framed |
| |||
|
| |||
hole and the angled portion extending down into the |
|
| ||
hole. |
|
| ANGLE | |
|
|
| ||
Firestop spacers are not available for nor are they |
| FIRESTOP | ||
|
| |||
required on vertical walls. |
|
| CHIMNEY | |
DO NOT put any sealant around the area where the |
| SUPPORT | ||
ANGLED STRAP | STRAP | |||
outer pipe slides through the firestop spacer. If you | (must be tight) | |||
| ||||
seal this area, it may cause a fire hazard. | FP270/271 |
| ||
Fig. 17 Attach straps to a structural framing member. | ||||
Canadian Requirements | ||||
|
| |||
for Insulation Shield |
|
| ||
In Canada, an attic | Attic Installation | Ceiling Installation |
| |
insulation shield is |
|
|
| |
required to prevent attic |
| NAILS (4) |
| |
insulation from contact- |
|
| ||
|
| JOIST | ||
ing the chimney sec- |
|
| ||
| FIRESTOP |
| ||
tion. Framing dimen- |
|
| ||
| SPACER |
| ||
sions for the chimney |
|
| ||
|
|
| ||
hole should measure |
|
| FIRESTOP | |
14¹⁄₂" x 14¹⁄₂". An attic |
| JOIST | SPACER | |
|
| |||
shield MUST be in- |
|
| ||
|
|
| ||
stalled on top of attic |
|
|
| |
joists (above the floor |
|
| NAILS (4) | |
level). (Fig. 19) |
|
| ||
|
| FP593 | ||
|
|
| ||
| Fig. 18 Installing firestop spacer. |
|
|
12