Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters

VCBVMN, VCBVMP, VCPVMN, VCPVMP Specifications

 

 

Input Rating

Regulator

Inlet Gas Supply

Size

 

 

Gas

(Btu/Hr) Variable

Pressure

Pressure

of Heater

Weight

Models

Type

Min.

Max.

Setting

Min.

 

Max.

 

 

 

 

 

VCBV30MN

 

15,000

30,000

 

 

 

 

27” x 24” x 8B\,”

30 lbs.

VCBV20MN

Natural

10,000

20,000

3.0” w.c.

7.0” w.c.

 

10.5” w.c.

19C\,” x 22M\,” x 8Z\x”

22 lbs.

VCBV10MN

 

5,000

10,000

 

 

 

 

15Z\x” x 20M\zn” x 7M\,”

17 lbs.

VCBV30MP

 

15,000

30,000

 

 

 

 

27” x 24” x 8Z\x”

30 lbs.

VCBV20MP

LP

10,000

20,000

8.0” w.c.

11.0” w.c.

 

14.0” w.c.

19C\,” x 22M\,” x 8Z\x”

22 lbs.

VCBV10MP

 

5,000

10,000

 

 

 

 

15Z\x” x 20M\zn” x 7M\,”

17 lbs.

VCPV30MN

 

6,400

30,000

 

 

 

 

27” X 24” X 8B\,”

30 lbs.

VCPV18MN

Natural

6,400

18,000

6.0” w.c.

7.0” w.c.

 

10.5” w.c.

19C\,” x 22M\,” x 8Z\x”

22 lbs.

VCPV10MN

5,500

10,000

 

15Z\x” x 20M\,” x 7M\,”

17 lbs.

 

 

 

 

 

VCPV06MN

 

2,600

6,000

 

 

 

 

15Z\x” x 20M\,” x 7M\,”

17 lbs.

VCPV30MP

 

6,400

30,000

 

 

 

 

27” x 24” x 8Z\x”

30 lbs.

VCPV18MP

LP

6,400

18,000

10.0” w.c.

11.0” w.c.

 

14.0” w.c.

19C\,” x 22M\,” x 8Z\x”

22 lbs.

VCPV10MP

5,500

10,000

 

15Z\x” x 20M\,” x 7M\,”

17 lbs.

 

 

 

 

 

VCPV06MP

 

2,600

6,000

 

 

 

 

15Z\x” x 20M\,” x 7M\,”

17 lbs.

NOTES: For altitudes above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level.

DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET

Gas Control

Front

Panel

Grille

Frame

Body

Guard

Assembly

 

 

VERMONT

 

C

 

astings

VCBVMN/MP

3769

Front

Gas Control

Panel

 

Grille

Frame

Body

Guard

Assembly

 

VERMONT

Castings

VCPVMN/MP

3772

Fig. 1 Product identification.

Local Codes

VCBV30 / VCBV20 / VCBV10

VCPV30 / VCPV18 / VCPV10 / VCPV06

Certified to

ANSI Z21.11.2b-2002 Unvented Heaters

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Fuel Gas Code ANSI Z223.2, also know as NFPA54.

Available from:

 

American National

National Fire Protection

Standards Institute, Inc.

Association, Inc.

1430 Broadway

Batterymarch Park

New York, NY 10018

Quincy, MA 02269

Product Features

Safety Device

This heater has a pilot with an Oxygen Depletion Sensor shutt-off system (ODS). The ODS pilot is a required feature for vent-free heaters. The ODS pilot shuts off the heater if the normal air oxygen content is reduced to 18%.

Piezo Ignition System

This heater has a piezo ignitor. This system requires no matches, batteries or other sources to light the heater.

3

Page 3
Image 3
Vermont Casting VCPV06, VCPV30, VCPV18, VCPV10, VCBV30 Local Codes, Product Features Safety Device, Piezo Ignition System