Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters
VCBVMN, VCBVMP, VCPVMN, VCPVMP Specifications
|
| Input Rating | Regulator | Inlet Gas Supply | Size |
| |||
| Gas | (Btu/Hr) Variable | Pressure | Pressure | of Heater | Weight | |||
Models | Type | Min. | Max. | Setting | Min. |
| Max. |
|
|
|
|
| |||||||
VCBV30MN |
| 15,000 | 30,000 |
|
|
|
| 27” x 24” x 8B\,” | 30 lbs. |
VCBV20MN | Natural | 10,000 | 20,000 | 3.0” w.c. | 7.0” w.c. |
| 10.5” w.c. | 19C\,” x 22M\,” x 8Z\x” | 22 lbs. |
VCBV10MN |
| 5,000 | 10,000 |
|
|
|
| 15Z\x” x 20M\zn” x 7M\,” | 17 lbs. |
VCBV30MP |
| 15,000 | 30,000 |
|
|
|
| 27” x 24” x 8Z\x” | 30 lbs. |
VCBV20MP | LP | 10,000 | 20,000 | 8.0” w.c. | 11.0” w.c. |
| 14.0” w.c. | 19C\,” x 22M\,” x 8Z\x” | 22 lbs. |
VCBV10MP |
| 5,000 | 10,000 |
|
|
|
| 15Z\x” x 20M\zn” x 7M\,” | 17 lbs. |
VCPV30MN |
| 6,400 | 30,000 |
|
|
|
| 27” X 24” X 8B\,” | 30 lbs. |
VCPV18MN | Natural | 6,400 | 18,000 | 6.0” w.c. | 7.0” w.c. |
| 10.5” w.c. | 19C\,” x 22M\,” x 8Z\x” | 22 lbs. |
VCPV10MN | 5,500 | 10,000 |
| 15Z\x” x 20M\,” x 7M\,” | 17 lbs. | ||||
|
|
|
|
| |||||
VCPV06MN |
| 2,600 | 6,000 |
|
|
|
| 15Z\x” x 20M\,” x 7M\,” | 17 lbs. |
VCPV30MP |
| 6,400 | 30,000 |
|
|
|
| 27” x 24” x 8Z\x” | 30 lbs. |
VCPV18MP | LP | 6,400 | 18,000 | 10.0” w.c. | 11.0” w.c. |
| 14.0” w.c. | 19C\,” x 22M\,” x 8Z\x” | 22 lbs. |
VCPV10MP | 5,500 | 10,000 |
| 15Z\x” x 20M\,” x 7M\,” | 17 lbs. | ||||
|
|
|
|
| |||||
VCPV06MP |
| 2,600 | 6,000 |
|
|
|
| 15Z\x” x 20M\,” x 7M\,” | 17 lbs. |
NOTES: For altitudes above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level.
DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET
Gas Control
Front
Panel
Grille | Frame | |
Body | ||
Guard | ||
Assembly | ||
| ||
| VERMONT | |
| C | |
| astings |
VCBVMN/MP
3769
Front | Gas Control | |
Panel |
| |
Grille | Frame | |
Body | ||
Guard | ||
Assembly | ||
|
VERMONT
Castings
VCPVMN/MP
3772
Fig. 1 Product identification.
Local Codes
VCBV30 / VCBV20 / VCBV10
VCPV30 / VCPV18 / VCPV10 / VCPV06
Certified to
ANSI
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Fuel Gas Code ANSI Z223.2, also know as NFPA54.
Available from: |
|
American National | National Fire Protection |
Standards Institute, Inc. | Association, Inc. |
1430 Broadway | Batterymarch Park |
New York, NY 10018 | Quincy, MA 02269 |
Product Features
Safety Device
This heater has a pilot with an Oxygen Depletion Sensor
Piezo Ignition System
This heater has a piezo ignitor. This system requires no matches, batteries or other sources to light the heater.
3