Electrical Connections

Installation Manual

ENGLISH

Electrical Connections

General information￿￿The models may be powered at 240V or 208V. DANGER

Disconnect power before servicing the product. Failure to do so could result in death or electrical shock.

General information

The flexible conduit (supplied) 3 feet long (100 cm) located at the right rear of the cooktop bottom box should be connected directly to junction box. Do not cut the conduit. A U.L - or CSA - listed conduit connector must be provided at each end of the power supply cable (at the cooktop and at the junction box.) A time delay fuse or circuit breaker is recommended. Do not ground to a gas pipe. Do not have a fuse in the grounding or neutral circuit.

Fuse both supply (phase) lines.

Figure 12. Location of serial tag WARNING

￿￿The models may be powered at 240V or 208V.

This cooktop does not require a neutral connection. If the cooktop is to be completely enclosed in a cabinet, feed the cooktop cable through the opening in the cabinet. Make the electrical connection following the appropriate steps for your installation.

Your cooktop must be connected to the proper electrical voltage and frequency as specified in the table on the right.

Figure 12. Location of serial tagConnect with copper wire only

If the house has aluminum wiring, follow the procedure below:

1.Connect the aluminum wiring to the copper wire by using special connectors designed and Underwriters Laboratories-listed for joining copper to aluminum. Follow the electrical connector manufacturer's recommended procedure.

2.Aluminum/copper connection must conform with local codes and industry- accepted wiring practices.

Connect with copper wire only WARNING

Improper connection of aluminum house wiring to the copper leads can result in a serious problem.

 

 

 

Power Supply

 

 

 

Model

240 V 60 Hz

208 V 60 Hz

Approval

 

 

code

 

 

 

 

 

 

30”

VECTIM304

7,2kW

30A

6,2kW

29,8A

812T40IP

36”

VECTIM365

10,8kW

45A

9,7kW

46.6A

812V50IQ

National Fire Protection AssociationBatter/march Park Quincy, Massachusetts 02269

A three-wire, single phase, 240 Volt 60 cycle electrical system (properly circuit protected to meet Local Codes of NFPA No.70) must be provided. Unit must be properly grounded in accordance with local wiring code. The chart below recommends the minimum circuit protector and wire size if the appliance is the only unit on the circuit. If smaller sizes of wire are used, the unit efficiency will be reduced and a fire hazard may be created. It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.

National Fire Protection Association WARNING

This touch control works using optical light sensing technology. When first connecting electrically or after a power failure, any direct strong light over the sensor area may affect the touch control functionality. When powering on the unit make sure that no strong light is shining direct over the touch control zone, it can compromise the start-up sensor calibration resulting in an unresponsive touch control.