Verona VEFSGG 365 ND Injectors Table, Operations To Be Performed When Substituting The, 6a, 6b

Models: VEFSGG 365 ND

1 28
Download 28 pages 6.22 Kb
Page 20
Image 20
INJECTORS TABLE

INJECTORS TABLE

BURNERS

NOMINAL POWER

BTU/hr

REDUCED POWER

BTU/hr

LP/PROPANE

NATURAL GAS

11" W.C.P.

4" W.C.P.

 

 

Ø injector

Ø injector

[1/100 mm]

[1/100 mm]

 

 

Semi-rapid (SR)

6000

1500

72

118

 

 

 

 

 

 

Triple ring (TR)

12000

5000

102

170

 

 

 

 

 

 

 

Inner crown

2800 for NATURAL GAS (*)

1000 (*)

55

80

 

3500 for LP/PROPANE GAS (*)

(no. 1 central)

(no. 1 central)

 

 

 

Dual (D)

 

 

 

 

 

Outer crown

16000 for NATURAL GAS (#)

6500 for NATURAL GAS (*)

72

130

 

 

15000 for LP/PROPANE GAS (#)

4500 for LP/PROPANE GAS (*)

(no. 2 outer)

(no. 2 outer)

 

 

 

 

 

 

 

 

Oven burner (left)

13000

1500

109

180

 

 

 

 

 

Oven burner (right)

9000

1400

88

145

 

 

 

 

 

Broil burner (left)

8500

-

88

146

 

 

 

 

 

Broil burner (right)

8000

-

83

140

 

 

 

 

 

 

(*) Power calculated only with inner crown operating

(#) Power calculated with inner and outer crowns operating

Semi-rapid burner

J

Fig. 2.6a

Triple ring burner

J

Fig. 2.6b

OPERATIONS TO BE

PERFORMED WHEN

SUBSTITUTING THE

INJECTORS

Remove the gratings and the burner covers;

Using a wrench substitute the nozzle injectors “J” (figs. 2.6a - 2.6b - 2.6c) with those most suitable for the kind of gas for which it is to be used.

The burner are conceived in such a way so as not to require the regulation of the primary air.

DUAL burner

J

Injector for inner crown

J

Injectors for outer crowns

Fig. 2.6c

20

Page 20
Image 20
Verona VEFSGG 365 ND Injectors Table, Operations To Be Performed When Substituting The, Semi-rapidburner, DUAL burner, 6a