SETTING THE BURNER MINIMUM

 

 

 

SETTING THE BURNER MINIMUM

 

When switching from one type of gas to another, the minimum flow rate must also be

 

correct: the flame should not go out

even when passing suddenly from maximum to

 

minimum flame.

 

 

 

To regulate the flame follow the instructions below:

 

Semirapid and triple ring burners

 

–  Light the burner

 

 

 

–  Set the gas valve to

position

 

F

–  Remove the knob

 

 

 

 

 

– With a thin screwdriver turn the screw "F" until adjustment is correct (fig. 2.7).

 

Inside crown of DUAL burner

 

Fig. 2.7

 

 

–  Light the DUAL burner

 

 

 

–  Set the gas valve to

position

 

–  Remove the knob

 

 

H

– Using a screwdriver turn the screw "H" until the correct setting is obtained (fig. 2.8).

 

Outside crowns of DUAL burner

 

G

 

 

–  Light the DUAL burner

 

 

 

–  Set the gas valve to

position

 

 

–  Remove the knob

 

 

 

– Using a screwdriver turn the screw "G" until the correct setting is obtained (fig. 2.8).

 

For LP/PROPANE gas, tighten the adjustment screws completely.

Fig. 2.8