2.PRINTER SETUP

ENGLISH VERSION EO1-33058

2.13 Threshold Setting

2.13Threshold Setting (Cont.)

(3) Press the [PAUSE] key until the target sensor type is displayed.

<3>ADJUST SET

Black Mark Sensor

THRESHOLD<R>1.0V

 

 

 

 

 

 

[PAUSE]

 

<3> ADJUST SET

Feed Gap Sensor

THRESHOLD<T>1.4V

 

NOTE:

Pressing the [FEED] key one time causes a –0.1V change, up to 0.0V.

Pressing the [RESTART] key one time causes a +0.1V change, up to +4.0V.

(4)Set a threshold voltage (calculated in Sensor Adjustment Menu) by using the [FEED] or [RESTART] key, as shown below.

Threshold voltage = Midpoint between voltage at a print area and voltage at a gap/black mark

Black Mark Sensor

 

Feed Gap Sensor

THRESHOLD<R>4.0V

 

THRESHOLD<T>4.0V

THRESHOLD<R>3.9V

[RESTART]

THRESHOLD<T>3.9V

THRESHOLD<R>3.8V

 

THRESHOLD<T>3.8V

THRESHOLD<R>0.1V

[FEED]

THRESHOLD<T>0.1V

THRESHOLD<R>0.0V

 

THRESHOLD<T>0.0V

(5)After choosing a threshold voltage, press the [PAUSE] key.

(6)To check for a proper operation, issue the pre-printed media in online. If an error still occurs even after a manual threshold setting, change the threshold voltage a little, and retry.

E2-68

Page 82
Image 82
Toshiba B-SX4T owner manual THRESHOLDR4.0V THRESHOLDT4.0V THRESHOLDR3.9V