Toshiba B-SX4T owner manual Parameter Setting Cont, Solenoid Type Selection, R2-QM-R is installed

Models: B-SX4T

1 120
Download 120 pages 47.34 Kb
Page 35
Image 35
(11) Solenoid Type Selection

2. PRINTER SETUP

ENGLISH VERSION EO1-33058

2.9 Setting an Operating Environment

2.9.1Parameter Setting (Cont.)

NOTE:

Improper setting of the solenoid type may disable the ribbon saving function.

(11) Solenoid Type Selection

This parameter is to choose the solenoid type that is actually installed. When “<2>PARAMETER SET” appears, press the [PAUSE] key until the following display appears.

<2>PARAMETER SET SOLENOID TYPE1

Use the [FEED] or [RESTART] key to select a desired option.

[RESTART]

[FEED]

SOLENOID TYPE1

TDS-12C (Insulation tape is blue.)

SOLENOID TYPE2

TDS-16A (Stronger pull force type) (Insulation tape is black.)

NOTES:

1.

The ribbon saving function is

 

available only when an optional

 

ribbon saving module (B-9904-

 

R2-QM-R) is installed.

2.

Ribbon saving option should be

 

selected according to the head

 

lever position. Incorrect setting

 

may disable the proper ribbon

 

saving function.

3.

The ribbon saving function is

After selecting the solenoid type, press the [PAUSE] key.

(12) Ribbon Saving Function Selection

This parameter is to choose whether to activate the Ribbon saving function or not.

This function enables reducing the ribbon loss caused by taking up unused ribbon during non-print areas.

When “<2>PARAMETER SET” appears, press the [PAUSE] key until the following display appears.

<2>PARAMETER SET RBN SAVE ON (TAG)

Use the [FEED] or [RESTART] key to select a desired option.

activated when there is a 20-mm

or more non-print area in the

media feed direction.

4. Ribbon saving is enabled up to 4

areas per media.

[RESTART]

[FEED]

RBN SAVE ON (TAG)

Activated (When the head lever is set to “(2)TAG”.)

RBN SAVE ON (LBL)

Activated (When the head lever is set to “(1)LABEL”.)

RBN SAVE OFF

Not activated

After selecting the ribbon saving function, press the [PAUSE] key.

E2-21

Page 35
Image 35