2.PRINTER SETUP

ENGLISH VERSION EO1-33058

2.13 Threshold Setting

2.13Threshold Setting (Cont.)

„Storing a “No Media Level” Voltage

The following is how to set a “No media level” voltage that is used to detect a paper end.

If a “NO PAPER” is displayed even if the media has not run out yet, this voltage needs to be set again.

(1)Remove any media from the Black Mark Sensor/Feed Gap Sensor.

(2)A real-time voltages being detected by the Black Mark Sensor and Feed Gap Sensor are displayed.

<5>SENSOR ADJ. [PE]R0.1V T4.8V

Feed Gap Sensor

Black Mark Sensor

(3) Press and hold the [RESTART] or [FEED] key for about 3 seconds.

<5>SENSOR ADJ. [PE]R0.1VT4.8V*

(4)When storing a “no media level” voltage is completed, an asterisk “*”is displayed on the right side of a voltage. Press the [PAUSE] key.

(5)The message returns to “<5>SENSOR ADJ.”.

<5>SENSOR ADJ.

„Manual Threshold Setting

Then, set the calculated threshold voltage in the Parameter Fine Adjustment mode.

(1)While “<5>SENSOR ADJ.” is displayed, press the [FEED] or [RESTART] key until “<3>ADJUST SET” is displayed.

<3>ADJUST SET

(2)Press the [PAUSE] key to enter the Parameter Fine Adjustment Mode.

<3> ADJUST SET FEED ADJ.+10.0mm

E2-67