RS-232 COMMUNICATIONS
Baud rate: 19200 (fixed)
Bits: 8
No Parity
All protocol in ASCII format
TxD= Pin# 2, RxD= Pin# 3, GnD= Pin# 5 |
Command format (single command): command value (i.e. brightness 100).
NOTE: A space (not an underscore) or comma may be used between the command and its value.
Command string format: command, command value, command etc. (i.e. COMPOSITE, BRIGHTNESS 100, ANAMORPHIC, <CR>)
NOTE: In between commands, a comma or space may be used
NOTE: A carriage return must be used after each command or string.
Other notes:
•For command strings, a maximum of 255 characters can be used in a single string.
•PARAMETER min/max refers to a function’s minimum and maximum value range. Inputting values above or below their range may cause unpredictable (but not fatal) results.
23