ViewSonic 300 manual Indicator Message

Models: 300

1 30
Download 30 pages 42.54 Kb
Page 23
Image 23
Indicator Message

Indicator Message

The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the appropriate measures.

 

 

 

Table 10: Indicator Message

POWER

LAMP

TEMP

Contents

indicator

indicator

indicator

 

Lit

Turns off

Turns off

The Standby mode has been set.

orange

 

 

 

Blinks

Turns off

Turns off

Warming up. Please wait.

green

 

 

 

Lit

Turns off

Turns off

ON. Normal operation possible.

green

 

 

 

Blinks

Turns off

Turns off

Cooling down. Please wait.

orange

 

 

 

 

 

 

Cooling. Please wait.

Blinks red

-

-

The error has been detected. Take the appropriate measures

 

 

 

when the POWER indicator stops blinking.

 

 

 

Lamp is not lit.

 

 

 

The interior of the equipment may be too hot. Switch power

Blinks/

 

 

OFF, wait 20 minutes until the equipment cools, and check

Lit red

Turns off

whether the ventilation openings are blocked, whether the air

Lit red

 

 

filter is dirty, or whether the ambient temperature exceeds 35

 

 

 

 

 

 

°C. Switch power ON again. Replace the lamp if the same

 

 

 

problem occurs.

 

 

 

Lamp or lamp cover is not found, or hasn’t been fitted in

 

 

 

correctly.

Blinks/

Blinks red

Turns off

Switch power OFF, and wait for 45 minutes until the equipment

Lit red

cools. Check fitting of the lamp and lamp cover, and switch

 

 

 

power ON again. Contact your dealer if the same problem

 

 

 

occurs again.

 

 

 

The cooling fan is not operating.

Blinks/

 

 

Switch power OFF, and wait for 20 minutes until the equipment

Turns off

Blinks red

cools. Check for foreign matters in the fan, and switch power

Lit red

 

 

ON again. Contact your dealer if the same problem occurs

 

 

 

 

 

 

again.

 

 

 

 

 

 

 

The interior of the equipment is too hot.(*1)

 

 

 

Switch power OFF, and wait for 20 minutes until the equipment

Blinks/

 

 

cools. Check whether the ventilation openings

Turns off

Lit red

are blocked, whether the air filter is dirty, or whether the ambient

Lit red

 

 

temperature exceeds 35 °C. Then switch power

 

 

 

 

 

 

ON again. Contact your dealer if the same problem occurs

 

 

 

again.

 

 

 

The interior of the equipment is too cool.

Lit green

Blinks red

Blinks

Check whether the ambient temperature is below 0°C. Contact

red

you dealer if the same problem occurs when the ambient

 

 

 

 

 

temperature is 0~35 °C.

 

 

 

 

NOTE:

(*1) When the internal temperature becomes excessive power is switched OFF automatically for safety reasons, and the indicator is extinguished. Set the power switch to [O] and wait for 20 minutes until the equipment has cooled sufficiently.