Related messages (continued)

Message

Description

CHECK THE AIR FLOW

The internal portion temperature is rising.

 

Please turn the power OFF, and allow the unit to cool

 

down at least 20 minutes. After having confirmed the

 

following items, please turn the power ON again.

 

• Is there blockage of the air passage aperture?

 

• Is the air filter dirty?

 

• Does the peripheral temperature exceed 35°C?

 

• If the same indication is displayed after the treatment,

 

please set the HIGH at the FAN SPEED of the item

 

SERVICE of the OPTION menu.

CLEAN THE AIR FILTER

A note of precaution when cleaning the air filter.

POWER OFF FIRST,

Please immediately turn the power OFF, and clean or

THEN CLEAN THE AIR

change the air filter by referring to the “Air Filter”

FILTER.

section of this manual. After you have cleaned or

AFTER CLEANING THE

changed the air filter, please be sure to reset the filter

AIR FILTER,

timer. ( 39)

RESET THE FILTER

 

TIMER

 

NOTE • A lamp has a finite product life. Lamps are characterized by the fact that, after long hours of usage, a lamp will no longer light up, or the lamp will break or burst, etc. This projector is equipped with an automatic shut-down function, such that the power will automatically be turned off when lamp usage time has reached 2000 hours. Please be aware, however, that among lamp types, there are major differences in product lifetimes; a lamp may thus fail to light even prior to the functioning of the automatic shut-down function of this projector.