Panel Lamp Indicators

Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the Table below.

Please respond in accordance with the instructions within the Table.

POWER

LAMP

TEMP

Description

indicator

indicator

indicator

 

The orange

Turned OFF

Turned OFF

The STANDBY mode is set

lamp is lighted

(Not lighted)

(Not lighted)

 

Flashing of

Turned OFF

Turned OFF

The unit is warming up. Please wait.

the green

 

 

 

lamp

 

 

 

The green

Turned OFF

Turned OFF

The unit is in an ON state. Ordinary operations may be performed.

lamp is lighted

 

 

 

Flashing of

Turned OFF

Turned OFF

The unit is cooling down. Please wait.

the orange

 

 

 

lamp

 

 

 

Blinking of the

-

-

The unit is cooling down. Please wait.

red lamp

 

 

A certain error has been detected. Wait until the POWER indicator lamp

 

 

 

has finished flashing, and then perform the proper response measure

 

 

 

using the item descriptions below as reference.

The red lamp

The red lamp

Turned OFF

The lamp does not light.

is lighted, or

is lighted

 

There is a possibility that the interior portion has become heated. Turn

blinks

 

 

the power OFF and wait approximately 20 minutes. After the main unit

 

 

 

has cooled down, please confirm whether or not there is blockage of the

 

 

 

air passage aperture, whether or not the filter is dirty, and/or whether or

 

 

 

not the peripheral temperature exceeds 35°C, etc. After performing any

 

 

 

needed maintenance, turn the power ON again; if the same display is

 

 

 

displayed, then please change the lamp.

The red lamp

Blinking of the

Turned OFF

Either there is no lamp and/or lamp cover, or either of these has not

is lighted, or

red lamp

 

been properly fixed (attached). Turn the power OFF and wait approxi-

blinks

 

 

mately 45 minutes. After the main unit has sufficiently cooled down,

 

 

 

please make confirmation of the attachment state of the lamp and lamp

 

 

 

cover. After performing any needed maintenance, turn the power ON

 

 

 

again; if the same display is displayed, then please contact a sales store

 

 

 

or a service company.

The red lamp

Turned OFF

Blinking of the

The cooling fan is not operating. Turn the power OFF and wait approxi-

is lighted, or

 

red lamp

mately 20 minutes. After the main unit has cooled down, please make

blinks

 

 

confirmation that no foreign matter has become caught in the fan, etc.

 

 

 

After performing any needed maintenance, turn the power ON again; if

 

 

 

the same display is displayed, then please contact a sales store or a

 

 

 

service company.

The red lamp

Turned OFF

The red lamp is

There is a possibility that the interior portion has become heated. Turn

is lighted, or

 

lighted

the power OFF and wait approximately 20 minutes. After the main unit

blinks

 

 

has cooled down, please confirm whether or not there is blockage of the

 

 

 

air passage aperture, whether or not the filter is dirty, and/or whether or

 

 

 

not the peripheral temperature exceeds 35°C, etc. After performing any

 

 

 

needed maintenance, turn the power ON again; if the same display is

 

 

 

displayed, then please contact a sales store or a service company.

The green

Alternative blinking with the red

There is a possibility that the interior portion has become overcooled.

lamp is lighted

lamp

 

Please use the unit within the usage temperature parameters (0°C to

 

 

 

35°C). After performing any needed maintenance, turn the power ON

 

 

 

again; if the same display is displayed, then please contact a sales store

 

 

 

or a service company.

The green

Simultaneous blinking with the

This is a notification that it is time to clean the filter. After cleaning the fil-

lamp is lighted

red lamp

 

ter, operate the FILTER TIME portion of the OPTION Menu, and perform

 

 

 

reset of the FILTER TIME.

NOTE:

When the interior portion has become overheated, for safety purposes, the power source is automatically turned OFF, and the indicator lamps may also be turned OFF. Press the O” (power OFF) side of the main power switch, and wait for approximately 20 minutes. Please then use the unit only after having first confirmed that the unit has sufficiently cooled down.