E4
7 Preparation of the Oven
Separate mounting plate from oven by removing two
screws. See illustration below. Save these screws for use
in section Mounting Oven to Wall, figure /.
Mounting
Plate
Back of Microwave
figure
figure

4

8 Ventilation System (Preparing
Oven for Installation)
This Built-in Microwave Hood is designed for adaptation
to three types of hood ventilation systems. Select the
type required for your installation.
rEcirculating — non-vented, ductless.
Follow installation procedure (A). Recirculating requires
the use of the Charcoal Filter, which has already been
installed in the oven.
hOrizOntal Exhaust — outside ventilation.
Follow installation procedure (B).
VErtical Exhaust — outside ventilation.
Follow installation procedure (C).
(A) Recirculating: Non-Vented, Ductless
Operation
•The unit is shipped assembled for recirculating.
•The Exhaust Damper Assembly 7 is NOT REqUIRED
for recirculating operation.
(B) Horizontal Exhaust: Outside
Ventilation
figure
figure
5
1) HORIZONTAL EXHAUST: Remove 2 screws from back
edge and 3 screws from the top ce nter of Fan Cover Bracket.
Save 2 screws to be used later and dis card remaining 3.
Remove Fan Cover Bracket by sliding it in th e opposite
direction of the arrow on the Fa n Cover Bracket.
figure
figure
6Hood Fan Unit
2) HORIZONTAL EXHAUST: Lift Hood Fan Unit ca refully
and slip wires out of cavity.
•cauti On: Do not pull or stretch hood fan wiring.
figure
figure
7(A) Rotate 180˚
(B)
3) HORIZONTAL EXHAUST: Rotate the Hood Fan Unit 180˚
so that the fan blade openings a re facing the back of the
oven. See Figure 7 (A). Replace Hood Fa n Unit into the
oven. Be careful not to pinch the wire a nd the Hood Fan