Electrical & Gas Requirements

Electrical Requirements

Check your national and local codes regarding this unit. This range requires

3 wire or 4 wire, 240-208 VAC/60 Hz. See

“Electrical Connection” section for

grounding instructions. Must be fused seperately from any other circuit.

IMPORTANT: Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company. Please provide the service person with this manual before work begins.

Pressure Regulator:

• All heavy-duty, commercial type cooking

Flexible Connections:

If the unit is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must use a heavy-duty AGA design-certified flexible connector of at least 1/2” (1.3 cm) ID NPT (with suitable strain reliefs) in compliance with ANSI Z21.41 and Z21.69.

In Canada: CAN 1-6, 10-88 metal connectors for gas appliances and CAN

1-6.9 M79 quick disconnect devices for use with gas fuel.

In Massachusetts: This appliance must be installed with a 36” (3-foot) long flexible gas connector.

WARNING

Electrical shock hazard.

To avoid the risk of electrical

shock, personal injury or death; verify electrical power is turned

off at the breaker box and gas supply is

equipment must have a pressure regulator

on the incoming service line for safe and

efficient operation, since service pressure

may fluctuate with local demand. External

regulators are not required on this range

since a regulator is built into each unit at

2-3/4”

(7.0 cm)

2” dia.

(5.1 cm)

turned off until the range is installed and ready to operate, installation by an authorized installer only.

Gas Connection

The gas supply (service) line must be the same size or greater than the inlet line of the appliance. This range uses a 1/2” (1.3 cm) ID NPT (Sch40) inlet. Sealant on all pipe joints must be resistive to LP gas.

The range is designed specifically for natural gas or liquid propane (LP) gas. Before beginning installation verify that the model is compatible with the intended gas supply.

 

the factory. Under no condition bypass

 

this built-in regulator.

Manifold pressure should be checked with

 

a manometer, natural gas requires 5.0”

 

W.C.P. and LP gas requires 10.0” W.C.P.

 

Incoming line pressure upstream from the

 

regulator must be 1” W.C.P. higher than

 

the manifold pressure in order to check

 

the regulator. The regulator used on this

 

range can withstand a maximum input

 

pressure of 1/2” PSI (14.0” W.C.P.). If the

 

line pressure is in excess of that amount, a

 

step down regulator will be required.

The appliance must be disconnected from

 

the gas supply piping system during any

 

pressure testing of that system.

Gas connection in this area

2-1/2”

(6.4 cm)

1-3/4”

(4.4 cm)

23-

 

7/16”

31-1/16”

 

(59.5 cm)

(78.9 cm)

28-5/16”

(71.9 cm)

4-3/8”

(11.1 cm)

Gas or electrical connection in this area

Manual shut-off valve:

This installer-supplied valve must be installed in the gas service line before the appliance in the gas stream and in a location where it can be reached quickly in the event of

an emergency.

In Massachusetts: A “T” handle type manual valve must be installed in the gas supply line to the appliance.

10

11

Page 6
Image 6
Viking F20495 manual Electrical & Gas Requirements, Electrical shock hazard

F20495 specifications

Viking F20495 is a remarkable entry in the realm of high-performance marine vessels, designed to cater to the needs of both commercial and recreational users. As a robust and versatile boat, it exemplifies the perfect blend of traditional craftsmanship and modern technology, making it an ideal choice for various marine activities.

One of the standout features of the Viking F20495 is its sturdy construction. Built with a high-quality fiberglass hull, it ensures durability and longevity while maintaining a lightweight profile. This construction method not only enhances performance on the water but also minimizes maintenance concerns, allowing users to focus on their adventures rather than repairs.

In terms of size, the F20495 measures an impressive 20 feet in length, providing ample space for passengers and gear. The design incorporates a spacious cockpit, ideal for fishing, leisure activities, or social gatherings. Its ergonomic layout ensures comfort and ease of movement, integral for those long jaunts at sea.

Equipped with advanced propulsion technology, the Viking F20495 can feature a powerful outboard engine that delivers exceptional speed and fuel efficiency. This engine configuration allows for improved maneuverability, essential for navigating both calm waters and challenging conditions.

The vessel is also designed with safety in mind. Features such as a deep V-hull provide stability and reduce the risk of capsizing, while high-quality railings and non-slip surfaces promote secure movement around the deck. Additionally, the inclusion of state-of-the-art navigation and communication systems ensures that users can maintain contact with shore and navigate with confidence, even in unfamiliar territories.

Interior features abound in the Viking F20495, with comfortable seating and ample storage designed to enhance the overall user experience. Cabin facilities are often included, offering shelter from the elements and making overnight trips more enjoyable.

In summary, Viking F20495 stands out as a high-performance vessel that offers a perfect combination of style, technology, and practicality. With its robust construction, powerful engine options, and user-friendly design, it caters to both novice and experienced marine enthusiasts alike, making it a superb choice for anyone looking to explore the waterways.