Viking F20921B manual Natural Fixed Piping Connection, LP/PROPANE Fixed Piping Connection

Models: F20921B

1 10
Download 10 pages 32.43 Kb
Page 3
Image 3
Natural Fixed Piping Connection

Natural Fixed Piping Connection

Connection:

Standard Residential 1/2” ID gas service line - 1/2” NPT male with 1/2” flare adapter.

Operating Pressure:

4.0” W.C.P. Nat.

Supply Pressure:

6” to 14” W.C.P. Nat. If in excess of 14” W.C.P., a step-down regulator is required.

Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run and how deep to bury the lines. If the gas line is too small, the unit will not function properly.

To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 1/2” (1.3 cm) female flare adaptor to the 1/2” (1.3 cm) male flare adaptor on the regulator assembly. Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply. Attach the regulator assembly to the unit by pulling back the female coupler sleeve towards the regulator. Insert the coupler into the male coupler fitting on the sie burner until the sleeve snaps forward securing the connection. DO NOT forget to place the installer supplied gas valve in an accessible location.

NOTE: If using a Viking GSH12 flexible hose, remove the 3/8” flare adapter and attach hose to the the 1/2” (1.3 cm) male flare on the regulator assembly.

Female

Female coupler sleeve

Regulator

Male coupler fitting

LP/PROPANE Fixed Piping Connection

Connection:

Standard Residential 1/2” ID gas service line - 1/2” NPT male with 3/8” flare adapter.

Operating Pressure:

10.0” W.C.P. Nat.

Supply Pressure:

11” to 14” W.C.P. Nat. If in excess of 14” W.C.P., a step-down regulator is required.

Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run and how deep to bury the lines. If the gas line is too small, the unit will not function properly.

To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 3/8” female flare adaptor to the 3/8” male flare adaptor to the regulator assembly. Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply. Attach the regulator assembly to the unit with the 3/8” female flare adapter on the regulator assembly to the 3/8” male flare adaptor on the unit.

DO NOT forget to place the installer supplied gas valve in an accessible location.

Male coupler fitting 3/8” female flare adaptor

Regulator

3/8” Male flare adaptor

1/2” male flare adaptor

Regulator Assembly

Installer supplied flexible gas line with 1/2”

female flare adaptor or GHS12

3/8” male flare adaptor

Regulator Assembly

Installer supplied flexible gas line with 3/8”

female flare adaptor or GHS12

4

5

Page 3
Image 3
Viking F20921B manual Natural Fixed Piping Connection, LP/PROPANE Fixed Piping Connection, Regulator Assembly