Troubleshooting
Problem | Possible Cause | What To Do |
Refrigerator runs too | Condenser coils are dirty | Clean coils. See p. 29. |
frequently | Controls need to be | See p. 5 to adjust controls. |
| adjusted. | Check for internal |
| Door is not closing | obstructions that are |
| properly. | keeping door from closing |
|
| properly. |
|
| Refrigerator is not level. |
|
| See installation instructions |
|
| for details on how to level |
|
| your refrigerator. |
|
| Check gaskets for proper |
|
| seal, clean if necessary. |
|
| See p. 29. |
ICE and WATER
Problem | Possible Cause | What To Do | |
No indicator lights are lit | Freezer door is not closed | Verify that freezer door is | |
on dispenser control |
| closed. Power is removed | |
|
| from the control when | |
|
| freezer door is opened. |
|
| Refrigerator not plugged in. | Plug in refrigerator | |
| Fuse is blown, or circuit | Replace any blown fuses. | |
| breaker needs to be reset. | Check circuit breakers for | |
|
| any tripped circuits. |
|
| Power outage has | Call local power company | |
| occurred. | to report outage. | |
| Refrigerator is in Sabbath | See Sabbath Mode p. 8 |
|
| Mode. |
|
|
Ice Maker is not producing | Ice maker has just been | Wait 24 hours for ice | |
enough ice or ice is | installed or a large | production to restock after | |
malformed. | amount of ice has been | emptied. | |
| used. |
|
|
| Water pressure is low. | Water pressure must be | |
|
| between 35 - 100 pounds | |
|
| per square inch. A | |
|
| minimum pressure of 35 | |
|
| pounds per square inch is | |
|
| recommended for | |
|
| refrigerators with water | |
|
| filters. | |
| Water filter is clogged or | Change water filter, p. 21 | |
| needs to be changed. |
|
|
|
|
|
|
*Manufacturer is not responsible for property damage due to improper installation or water connection.
Troubleshooting
ICE and WATER
Problem |
| Possible Cause | What To Do |
Ice or Water are not |
| Freezer door is not closed. | Verify that freezer door is |
dispensed when pads |
|
| closed. Power is removed |
are pressed |
|
| from the control when |
|
|
| freezer door is opened. |
|
| Controls are in lock mode. | See Dispenser Lock p. 19 |
|
| Water tank is filling. | At initial use, there is an |
|
|
| approximate one to two |
|
|
| minute delay in dispensing |
|
|
| while the internal water |
|
|
| tank is filling. |
|
| Ice bin not installed | Reinstall ice bin, p. 16 |
|
| properly. |
|
|
| Ice maker has just been | Wait 24 hours for ice |
|
| installed or a large | production to restock after |
|
| amount of ice has been | emptied. |
|
| used. |
|
|
| Water pressure is low. | Water pressure must be |
|
|
| between 35 - 100 pounds |
|
|
| per square inch. A |
|
|
| minimum pressure of 35 |
|
|
| pounds per square inch is |
|
|
| recommended for |
|
|
| refrigerators with water |
|
|
| filters. |
|
| Water filter is clogged or | Change water filter, p. 21. |
Refrigerator is leaking |
| Plastic tubing was used | The manufacturer |
water |
| for water connection | recommends using copper |
|
|
| tubing. Plastic is less |
|
|
| durable and can cause |
|
|
| leakage*. |
|
| Improper water valve | Check water connection |
|
| installed. | procedure in installation |
|
|
| instructions. Self piercing |
|
|
| and 3/16” saddle valves |
|
|
| cause low water pressure |
|
|
| and may clog the line over |
|
|
| time.* |
|
|
|
|
*Manufacturer is not responsible for property damage due to improper installation or water connection.
38 | 39 |