Viking PSFEM1xxxGQxxx manual Electrical Characteristics, STANDBY IMMEDIATE Command, Supply Voltage

Models: PSFEM1xxxGQxxx

1 33
Download 33 pages 18.54 Kb
Page 14
Image 14
2.2.1 STANDBY IMMEDIATE Command

2.2.1 STANDBY IMMEDIATE Command

The Power-On-to-Ready time assumes a proper shutdown (power removal preceded by STANDBY IMMEDIATE command. A STANDBY IMMEDIATE before power down always performs a graceful shutdown and does not require the use of the hold-up circuit. Note that SMART attribute 174 "Unexpected Power Loss" records the number of non-graceful power cycle events.

Table 2-4: STANDBY IMMEDIATE Timing

Power Cycle Endurance

Min

Max

Unit

STANDBY IMMEDIATE to WE completed

-

72.9

ms

Notes:

1.From Standby Immediate command to NAND Write Protect enable.

2.3Electrical Characteristics

2.3.1 Absolute Maximum Ratings

Values shown are stress ratings only. Functional operation outside normal operating values is not implied. Extended exposure to absolute maximum ratings may affect reliability.

Table 2-5: Absolute Maximum Ratings

Description

Min

Max

Unit

Maximum Voltage Range for Vin

-0.2

6

V

Maximum Temperature Range

-40

85

c

 

2.3.2 Supply Voltage

 

 

 

 

 

 

The operating voltage is 5V.

 

 

 

 

 

 

Table 2-6: Operating Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

Min

Max

Unit

 

Operating Voltage for 5.0 V (+/- 5%)

 

4.75

 

5.25

V

 

Table 2-8: Current Draw – SATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

Typical1

 

 

Unit

 

 

Read/Writes (Average RMS)

 

215 / 310

 

 

mA

 

 

Idle

 

25

 

 

mA

 

 

Slumber

 

10

 

 

mA

 

 

Notes:

 

 

 

 

 

 

1. Measured using 16GB SLC, VRFEM1016GQCQS

Manual

PSFEM1xxxGQxxx

Revision B www.vikingtechnology.com

9/11/2014

Viking Technology

Page 14 of 33

Page 14
Image 14
Viking PSFEM1xxxGQxxx Electrical Characteristics, STANDBY IMMEDIATE Command, Absolute Maximum Ratings, Supply Voltage