Table 5-4: S.M.A.R.T. Command Set

Value (hex)

Command

00-CF

Reserved

D0

S.M.A.R.T. read attributes

D1*

S.M.A.R.T. read threshold

D2

S.M.A.R.T. enable/disable attribute autosave

D3*

S.M.A.R.T. save attribute values

D4

S.M.A.R.T. execute off-line immediate

D5

S.M.A.R.T. read log sector

D6

S.M.A.R.T. write log sector

D7*

S.M.A.R.T. write attribute threshold

D8

S.M.A.R.T. enable operations

D9

S.M.A.R.T. disable operations

DA

S.M.A.R.T. return status

DB

S.M.A.R.T. enable/disable automatic off-line

DC-FF

Reserved (Vendor Specific)

* Note that D1, D3, and D7 have been made obsolete in the

ATA-8 specification.

5.1.2.1Extended SMART Attributes

Table 5-5: Extended SMART Attribute Table

SMART Attribute

 

ID

Description

01h

Read Error Rate

05h

Reallocated sector Count

09h

Power-On hours Count

 

Drive Power Cycle Count (Number of accumulation of power

0Ch

on/off cycles)

20h

Write Protect

A7h

SSD Protect Mode

 

SATA PHY Error Count (only record from power on, when power

 

off this value will clear to zero) this value include all PHY error

 

count, ex data FIS CRC ,code error, disparity error ,command

A8h

FIS CRC

A9h

Total Bad Block Count

 

Max Bad Block Count (will show early bad and later bad block

AAh

count)

ACh

Erase Fail Count

ADh

Erase count (average, max, erase count)

B1h

Wear Range delta

B5h

Program Fail Count

Manual

PSFEM1xxxGQxxx

Revision B www.vikingtechnology.com

9/11/2014

Viking Technology

Page 28 of 33

Page 28
Image 28
Viking PSFEM1xxxGQxxx Extended Smart Attributes, S.M.A.R.T. Command Set, Extended Smart Attribute Table, Value hex Command