Viking PSFEM1xxxGQxxx manual Word, V Variable, Default Value, Description, X Both

Models: PSFEM1xxxGQxxx

1 33
Download 33 pages 18.54 Kb
Page 24
Image 24
Manual background

 

 

F: Fixed

 

 

 

Word

 

V: Variable

 

Default Value

Description

 

 

X: Both

 

 

 

66

 

F

 

0078h

Manufacturer’s recommended Multiword DMA

 

 

transfer cycle time

 

 

 

 

 

67

 

F

 

0078h

Minimum PIO transfer cycle time without flow

 

 

control

 

 

 

 

 

68

 

F

 

0078h

Minimum PIO transfer cycle time with IORDY

 

 

flow control

 

 

 

 

 

69

 

F

 

0100h

Additional Supported (support download

 

 

microcode DMA)

 

 

 

 

 

70

 

F

 

0000h

Reserved

71-74

 

F

 

000000000000000

Reserved for the IDENTIFY PACKET DEVICE

 

 

0h

command

 

 

 

 

75

 

F

 

001Fh

Queue depth

76

 

F

 

0706h

Serial SATA capabilities

77

 

F

 

0000h

Reserved for future Serial ATA definition

78

 

F

 

0044h

Serial ATA features supported

79

 

V

 

0040H

Serial ATA features enabled

80

 

F

 

01F8h

Major Version Number

81

 

F

 

0000h

Minor Version Number

82

 

F

 

346Bh

Command set supported

83

 

F

 

70D9h

Command set supported

84

 

F

 

6023h

Command set/feature supported extension

85

 

V

 

3469h

Command set/feature enabled

86

 

V

 

BC01h

Command set/feature enabled

87

 

V

 

6023h

Command set/feature default

88

 

V

 

003Fh

Ultra DMA Modes

89

 

F

 

001Eh

Time required for security erase unit

 

 

completion

 

 

 

 

 

90

 

F

 

001Eh

Time required for Enhanced security erase

 

 

completion

 

 

 

 

 

91

 

V

 

0000h

Current advanced power management value

92

 

V

 

FFFEh

Master Password Revision Code

 

 

 

 

 

Hardware reset result. The contents of the bits

93

 

F

 

0000h

(12:0) of this word shall change only during

 

 

 

 

 

the execution of s hardware reset.

94

 

V

 

0000h

Vendor’s recommended and actual acoustic

 

 

management value

 

 

 

 

 

95

 

F

 

0000h

Stream Minimum Request Size

96

 

V

 

0000h

Streaming Transfer Time – DMA

97

 

V

 

0000h

Streaming Access Latency – DMA and PIO

98-99

 

F

 

0000h

Streaming Performance Granularity

100-103

 

V

 

8GB-256GB

Maximum user LBA for 48 bit Address feature

 

 

set

 

 

 

 

 

104

 

V

 

0000h

Streaming Transfer Time – PIO

105

 

F

 

0000h

Maximum number of 512-byte blocks per

 

 

DATA SET MANAGEMENT command

 

 

 

 

 

106

 

F

 

4000h

Physical sector size / Logical sector size

Manual

PSFEM1xxxGQxxx

Revision B www.vikingtechnology.com

9/11/2014

Viking Technology

Page 24 of 33

Page 24
Image 24
Viking PSFEM1xxxGQxxx manual Word, V Variable, Default Value, Description, X Both