Viking CRVDD330R Take Measurements Continued, Plan The Ductwork, Viking Range, Llc, calculation.3

Models: RVDD336R CRVDD330R CRVDD336R CRVDD345R RVDD345R RVDD330R

1 24
Download 24 pages 53.14 Kb
Page 3
Image 3
VIKING RANGE, LLC

VIKING RANGE, LLC

Downdraft Ventilators

 

 

TAKE MEASUREMENTS (CONTINUED)

 

Interior Blower Installation

Exterior Blower Installation

SIDE VIEW

OF DOWNDRAFT

WITH

VIDV500

INTERIOR

BLOWER

VIDV500

INTERIOR

BLOWER

SIDE VIEW

OF DOWNDRAFT

WITH

10" ROUND ELBOW

(for connection

to VEDV900 or VEDV1200

(DIPR150RSS only))

PLAN THE DUCTWORK

Interior Blower Installation

Exterior Blower Installation

1.The interior down- draft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to 6" round). Three different discharge directions are avail- able with side-to- side adjustment for accurate alignment of ductwork.

LEFT

DISCHARGE

1.The exterior downdraft blower system is designed for use with 10" round duct- work.

2.For best performance: Plan ducting which has the shortest length of ductwork and a minimum number of elbows. Check location of floor joists, wall studs, elec- trical wiring or plumbing for possible interference.

2. For best performance:

 

RIGHT

Choose the ducting

 

DISCHARGE

option which allows

 

 

the shortest length

DOWN DISCHARGE

of ductwork and a

 

 

 

minimum number of elbows and transitions. Check location

of floor joists, wall studs, electrical wiring or plumbing for

possible interference.

 

 

 

 

 

 

6" ROUND

 

3-1/4" X 10" TO 6" RD.

3-1/4" X 10"

ELBOW

 

TRANSITION

 

90O ELBOW

EQUALS 6 FT. OF

 

EQUALS

 

 

 

2 FT. OF

 

EQUALS 8 FT. OF

STRAIGHT DUCT

 

STRAIGHT DUCT

 

 

 

STRAIGHT DUCT

 

 

 

 

 

 

 

 

 

3.The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The chart, above, shows equivalent feet of elbows and transitions. The number of feet of straight duct plus the equivalent feet of transitions and/or elbows to be used should equal 40 feet or less.

NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this

calculation.3

 

10" ROUND

 

DISCHARGE

 

PLATE

 

 

10" ROUND

EQUALS 6 FT. OF

 

ELBOW

STRAIGHT DUCT

 

 

 

 

3.The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The illustration, above, shows equivalent feet of a 10" round elbow.The number of feet of straight duct plus the equivalent feet of elbows to be used should equal 40 feet or less.

NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation.

Page 3
Image 3
Viking CRVDD330R Take Measurements Continued, Plan The Ductwork, Viking Range, Llc, to VEDV900 or VEDV1200, calculation.3