Viking RVDD330R Install Electrical Wiring, Install Cooktop, applicable codes and standards

Models: RVDD336R CRVDD330R CRVDD336R CRVDD345R RVDD345R RVDD330R

1 24
Download 24 pages 53.14 Kb
Page 8
Image 8
INSTALL ELECTRICAL WIRING

VIKING RANGE, LLC

Downdraft Ventilators

 

 

INSTALL ELECTRICAL WIRING

Interior Blower Installation

!

CAUTION: All electrical wiring should be done

by a qualified person(s) in accordance with all

applicable codes and standards.

1.Mount a standard wiring box, with 3-pronged receptacle, inside the cabinet. Make sure the downdraft's power cord can easily reach it.

2.Run appropriate power cable into cabinet and connect it to receptacle.

3.Plug the downdraft's power cord into the outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.

INSTALL COOKTOP

Exterior Blower Installation

!

CAUTION: All electrical wiring should be done

by a qualified person(s) in accordance with all

applicable codes and standards.

1.Mount a standard wiring box, with 3-pronged grounded recep- tacle, inside the kitchen cabinet. Make sure the downdraft's power cord can easily reach it.

2.Run appropriate power cabinet into cabinet and connect it to electrical box and receptacle.

3.Exterior blower may not exceed 6.0 Amp rating.

4.Run 2-wire plus ground power cable from the remote blower to wiring box on 10" round discharge plate.

5.Connect downdraft wiring to power cable from remote blower. Wire black to black, white to white, and green to green or bare wire.

6.Replace wiring box cover.

7.Plug the downdraft's power cord into outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.

All Units

"R" MODEL

DOWNDRAFT

1. Align the cooktop with the downdraft and fasten cooktop in place.

Note: Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent is raised and lowered.There should be a gap of 1/32" - 1/16" between the back of the cooktop and the front of the downdraft cover.

REMOTE

CONTROL

COUNTERTOP

Note:

The downdraft remote control must be mounted into the coun- tertop, at least 4" from cook top or range top edge.

8

Page 8
Image 8
Viking RVDD330R Install Electrical Wiring, Install Cooktop, CAUTION All electrical wiring should be done, All Units