BUILT-IN CLEARANCE DIMENSIONS

Min. 6”

(15.2 cm)

to combustible

surfaces

15” W.

FRONT VIEW

155/16” (38.9 cm)

Min. 6”

(15.2 cm)

to combustible

surfaces

24” W.

FRONT VIEW

261/4”” (66.7 cm)

SIDE VIEW

11 3/8”

(28.9 cm)

PERFORMANCE CHECKLIST

A qualified installer should carry out the following checks:

All internal packaging removed.

Specified clearances maintained to combustible materials.

Pressure regulator connected and set.

Manual shut-off valve installed and accessible.

Check air shutter adjustment - sharp blue flame, no yellow tipping.

Check for gas leaks (odors) at all gas connections.

Each burner lights satisfactory, individually or with adjacent burners lit.

Any adjustments necessary that are the result of the installer not following instructions will be responsibility of the installer, dealer or the end user of the product.