NATURAL FIXED PIPING CONNECTION

Connection:

Standard Residential 1/2” ID gas service line - 1/2” NPT male with 1/2” flare adapter.

Operating Pressure:

4.0” W.C.P. Nat.

Supply Pressure:

6” to 14” W.C.P. Nat. If in excess of 14” W.C.P., a step-down regulator is required.

Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run and how deep to bury the lines. If the gas line is too small, the grill will not function properly.

To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 1/2” (1.3 cm) female flare adapter to the 1/2” (1.3 cm) male flare adapter on the regulator assembly. Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply. Attach the regulator assembly to the grill unit by pulling back the female coupler sleeve towards the regulator. Insert the coupler into the male coupler fitting on the grill until the sleeve snaps forward securing the connection. DO NOT forget to place the installer supplied gas valve in an accessible location.

NOTE: If using a Viking GSH12 flexible hose, remove the 3/8” flare adapter and attach hose to the 1/2” (1.3 cm) male flare on the regulator assembly.

Female coupler sleeve

Regulator

Male

 

coupler

Installer supplied

fitting

shut-off valve must

 

be easily accessible

1/2” male flare adapter

Regulator Assembly

Installer supplied flexible gas line with 1/2” female flare adapter or Viking GHS12

4

Page 4
Image 4
Viking TruSearTM manual Natural Fixed Piping Connection