DIAGNOSTIC CHECK POINTS (con’t)
E4 Thermister inputs (measured with thermisters disconnected).
1 to 8 3 to 4.5 VDC – TE2 (Evaporator Thermister #2)
2 to 9 3 to 4.5 VDC – TC1 (Compartment Thermister #1) 3 to 10 3 to 4.5 VDC – TE1 (Evaporator Thermister #1)
4 to 11 3 to 4.5 VDC – TC3 (Compartment Thermister #3) 5 to 12 3 to 4.5 VDC – TE3 (Evaporator Thermister #3)
6 to 13 3 to 4.5 VDC – TC2 (Compartment Thermister #2) 7 to 14 3 to 4.5 VDC
Compressor Relay | (use E3 – 16 as common for measurements) | ||
Com | 115 | VAC continuous (power line supply). | |
NO | 115 | VAC when compressor is running. | |
NC | Not connected. |
Alarm wires | (check for continuity – these are contact closures only) |
Black | Common |
Red | Normally closed (in no – alarm condition) |
White | Normally open (in no – alarm condition) |
Display Board (IDB5D
E1 | Display Board receive |
1+5VDC
2data signals
3ground
E2 | Futaba VFD display data connection |
TE = Thermister / Evaporator
Thermister Tolerance ± 2 degrees.