| TROUBLESHOOTING GUIDE (con’t) | ||||
| PROBLEM |
| POSSIBLE CAUSE |
| CORRECTION |
| |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| 4. | No Power from | 4. | Check E15 to ground (See |
|
|
|
|
| Control Board |
| page 14). |
|
|
|
|
|
|
|
|
|
| I. | Control Panel | 1. | Control Panel Ribbon | 1. | Check control panel ribbon |
|
| Keys Inoperative or |
| Cable Plugged in |
| cable (silver area on the ribbon |
| |
| Malfunctioning |
| Wrong |
| cable terminal should be |
| |
|
|
|
|
|
| facing away from the control |
|
|
|
|
|
|
| board). Plug in correctly if |
|
|
|
| 2. | Control Panel or Ribbon |
| Incorrect. |
|
|
|
| 2. | Check E2 test points page 14. |
| ||
|
|
|
| Cable Defective (Or) |
|
|
|
|
|
|
| No Signal Read at |
|
|
|
|
|
|
| Control Board. |
|
|
|
| J. | LED’s Do Not | 1. | Unit Switched Off | 1. | Press unit On/Off key |
|
| Illuminate. | 2. | LED Ribbon Cable | 2. | Check LED ribbon cable. Plug |
| |
|
|
|
| Plugged in Wrong. |
| in correctly if incorrect. |
|
|
|
| 3. | No Data from Control | 3. | Replace control board. |
|
|
|
|
| Board. |
|
|
|
| K. All LED’s Stay | 1. | Bad Data from Control | 1. | Replace control board. |
| |
| Illuminated. |
| Board. |
|
|
| |
|
|
|
|
|
|
|
|
| L. | Same Segment(s) | 1. | Bad Data from Control | 1. | Replace control board. |
|
| Missing From All |
| Board. |
|
|
| |
| Display Windows |
|
|
|
|
| |
|
|
|
|
|
|
| |
| M. Segment(s) Miss- | 1. | Bad LED Board in | 1. | Replace control panel assembly. |
| |
| Ing From Only one |
| Control Panel. |
|
|
| |
| Display Window. |
|
|
|
|
| |
|
|
|
|
|
|
| |
| N. Door or Unit | 1. | See Page 12 this Manual | 1. | See page 12 this manual. |
| |
|
|
|
|
|
|
|
|