TROUBLESHOOTING GUIDE (con’t)

 

PROBLEM

 

POSSIBLE CAUSE

 

CORRECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

No Power from

4.

Check E15 to ground (See

 

 

 

 

 

Control Board

 

page 14).

 

 

 

 

 

 

 

 

 

 

I.

Control Panel

1.

Control Panel Ribbon

1.

Check control panel ribbon

 

 

Keys Inoperative or

 

Cable Plugged in

 

cable (silver area on the ribbon

 

 

Malfunctioning

 

Wrong

 

cable terminal should be

 

 

 

 

 

 

 

facing away from the control

 

 

 

 

 

 

 

board). Plug in correctly if

 

 

 

 

2.

Control Panel or Ribbon

 

Incorrect.

 

 

 

 

2.

Check E2 test points page 14.

 

 

 

 

 

Cable Defective (Or)

 

 

 

 

 

 

 

No Signal Read at

 

 

 

 

 

 

 

Control Board.

 

 

 

 

J.

LED’s Do Not

1.

Unit Switched Off

1.

Press unit On/Off key

 

 

Illuminate.

2.

LED Ribbon Cable

2.

Check LED ribbon cable. Plug

 

 

 

 

 

Plugged in Wrong.

 

in correctly if incorrect.

 

 

 

 

3.

No Data from Control

3.

Replace control board.

 

 

 

 

 

Board.

 

 

 

 

K. All LED’s Stay

1.

Bad Data from Control

1.

Replace control board.

 

 

Illuminated.

 

Board.

 

 

 

 

 

 

 

 

 

 

 

 

L.

Same Segment(s)

1.

Bad Data from Control

1.

Replace control board.

 

 

Missing From All

 

Board.

 

 

 

 

Display Windows

 

 

 

 

 

 

 

 

 

 

 

 

 

M. Segment(s) Miss-

1.

Bad LED Board in

1.

Replace control panel assembly.

 

 

Ing From Only one

 

Control Panel.

 

 

 

 

Display Window.

 

 

 

 

 

 

 

 

 

 

 

 

 

N. Door or Unit

1.

See Page 12 this Manual

1.

See page 12 this manual.

 

 

 

 

 

 

 

 

 

25

Page 24
Image 24