General Information:

General Information:

 

 

 

 

 

 

Approved Board Certification

 

CSA – UL

 

 

 

Suction

 

0.256” + 0.005” / - 0.003”

 

 

Discharge

 

0.194” + 0.003” / - 0.003”

 

 

Process

 

0.256” + 0.005” / - 0.003”

 

 

Mechanical Data:

 

 

 

 

 

 

Low Starting Torque (LST)

 

 

 

 

 

 

Lubricant Charge

 

6.76 fl. Oz.

 

 

 

Lubricant type

 

ESTER

 

 

 

Lubricant Viscosity @ 40° C

 

ISO 22

 

 

 

Weight (with Oil Charge)

 

15.43 lbs.

 

 

 

Nitrogen Charge

 

2.84 to 4.27 psig.

 

 

Application:

 

 

 

 

 

 

Evaporating Temperature range

 

14°F to -31°F

 

 

Refrigerant

 

 

R134a

 

 

 

Refrigerant Charge

 

 

7.5 oz.

 

 

 

Expanding Device

 

 

Capillary Tube

 

 

Compressor Cooling

 

 

Operating Range (60Hz)

 

 

LBP 32° C Ambient Temp.

98 to 140V

 

 

 

LBP 43° C Ambient Temp

98 to 140V

 

 

 

Maximum Condensing Pressures

 

 

 

 

 

Operating

 

 

230 psig.

 

 

 

Peak

 

 

293 psig.

 

 

 

Electrical Data:

 

 

 

 

 

 

Normal Voltage

 

115VAC – 60Hz

 

 

 

Start Winding Resistance

 

21.20 (at 77°F) ± 8%

 

 

Run Winding Resistance

 

7.90 (at 77°F) ± 8%

 

 

Locked Rotor Amperage (60Hz)

9.80 Amps.

 

 

 

Full Load Amperage (60Hz)

 

1.20 Amps

 

 

 

Check Point Data:

 

 

 

 

 

 

Test Conditions: @115V - 60Hz (Evaporator

Temp.-10°F

/

Condensing

Temp.130°F)

 

 

 

 

 

 

Cooling Capacity ± 5%

275 Btu/h

81 Watts

 

 

 

Power Consumption ± 5%

 

 

75 Watts

 

 

 

Current Consumption ± 5%

 

 

0.98 Amps

 

 

16

Page 15
Image 15
Viking VCWB300 manual General Information, Mechanical Data, Application, Electrical Data, Check Point Data