TROUBLESHOOTING GUIDE
PROBLEM | POSSIBLE CAUSE |
|
| CORRECTION |
| |
A. Warm temperature | 1. Control set too warm | Check | ||||
in all Wine storage |
| points colder. |
|
| ||
compartments. |
|
|
|
|
|
|
| 2. Unit in Showroom | Adjust | ||||
| Mode | for | compressor | and condenser | ||
|
| fan operation. If they do not | ||||
|
| energize, switch unit OFF then | ||||
|
| press | and | hold | upper | |
|
| compartment colder & | warmer | |||
|
| keys while pressing unit On/OFF | ||||
|
| key. |
|
|
| |
|
|
| ||||
| 3. Unit Recently Energized | Allow 24 hours for unit to | ||||
|
| pull down. |
|
| ||
|
|
|
|
| ||
| 4. Unit Recently Stocked | Instruct customer. |
|
| ||
| 5. High Room Ambient | Instruct customer that unit | ||||
|
| performs best between 60°F / | ||||
|
| 15°C |
| |||
| 6. Door Ajar |
|
|
|
|
|
| a. Wine rack obstruction | a. | Adjust wine rack. |
| ||
| b. Door out of adjustment | b. | See door adjustment |
| ||
|
|
| procedures (See page 11) | |||
|
|
| in this manual. |
| ||
| c. Door or cabinet hinge | c. | Check hinges. Replace if | |||
| problem. |
| defective. |
|
| |
| 7. Evaporator Fan Circuit |
|
|
|
|
|
| Fault |
|
|
|
|
|
| a. Evaporator fans in all | a. Check for 115VAC input | ||||
| compartments not |
| to the control module. (See | |||
| functioning. |
| page 14) |
|
| |
| b. Only one compartment | b1. Check wiring from the | ||||
| evaporator fan not |
| control module to the |
| ||
| operating. |
| evaporator fan. |
| ||
|
| (E3 pin # 12 – compartment #1, | ||||
|
| E3 pin #13 – compartment #2, | ||||
|
| E3 pin #14 – compartment #3) | ||||
|
|
|
|
|
|
|
21