VENTILATION

Built-In VersaVent™ Rear Downdraft

Installation Requirements

VIPR Professional

VIPR Professional

DIPR Designer

Downdraft

Downdraft w/Remote

Downdraft w/Remote

 

 

 

 

UTILITY REQUIREMENTS

 

 

 

 

DUCTING

Check with a qualified and trained installer or local codes for makeup air requirements, if any.

Max. duct run length (see Installation Notes & Accessories)

For best performance, use the shortest length of ductwork and a minimum number of elbows.

The system will operate most efficiently when the ductwork does not exceed 40’ of equivalent duct. For longer duct runs, increase duct size and contact a qualified and trained installer.

Straight runs and gradual turns are best; for example, each 90° elbow is equivalent to 5’ – 10’ (152.4 – 304.8 cm) of straight run.

o6” or 10” round elbow= 6’ of straight duct

o3-1/4” x 10” to 6” round transition= 2’ of straight duct

o3-1/4” x 10” 90° elbow= 8’ of straight duct

Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.

GAS

• Not applicable

ELECTRICAL

2’-long power cord with 3- pronged plug included

Internal blowers require a grounded outlet within reach of the power cord

External blowers require direct

hardwiring with 2-wire with ground, using locally-supplied wire, and connected to the downdraft plug (included)

120 VAC/60 Hz

Max. amp usage (rating does not include recommended ventilator kit rating—See Installation Notes & Accessories)

PLUMBING

• Not applicable

Model

Ventilator Kits

InteriorExterior

Duct Size

InteriorExterior

Max. Amps

Interior Exterior

VIPR101

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

VIPR161

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

VIPR181

VIDV500

VEDV900/1200

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7/3.0

VIPR101R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

VIPR161R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

VIPR181R

VIDV500

VEDV900/1200

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7/3.0

DIPR100R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

DIPR160R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

DIPR150R

VIDV500

VEDV900

3–1/4” x 10” (8.3 x 25.4 cm)

10” (25.4 cm)

4.0

5.7

Note: Proper installation/ ducting is extremely important to ensure maximum performance. Use a qualified and trained installer.

P L A N N I N G A N D D E S I G N G U I D E

R E L E A S E D 1 2 / 1 / 0 7

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE

Page 4