OPERATION

DESCRIPTION OF OPERATING SEQUENCE

The following is a description of component functions during oven operation.

OFF CONDITION

Closing the door activates the door sensing switch and secondary interlock switch. (In this condition, the monitor switch contacts are opened.)

When oven is plugged in, 120 volts A.C. is supplied to the control unit. (Figure O-1).

1.The display will show flashing"WELCOME,

PRESS CLEAR"

To set any program or set the clock, you must first touch the STOP/CLEAR pad. The display will clear, and " : " will appear.

COOKING CONDITION

Program desired cooking time by touching the NUMBER pads. Program the power level by touching the POWER LEVEL pad and then a Number pad.

When the START pad is touched, the following operations occur:

1.The contacts of relays are closed and components connected to the relays are turned on as follows.

(For details, refer to Figure O-2)

RELAY

CONNECTED COMPONENTS

RY-1

oven lamp/turntable motor/fan motor

 

 

RY-2

power transformer

2.120 volts A.C. is supplied to the primary winding of the power transformer and is converted to about 3.3 volts A.C. output on the filament winding, and approximately 2370 volts A.C. on the high voltage winding.

3.The filament winding voltage heats the magnetron filament and the H.V. winding voltage is sent to a voltage doubler circuit.

4.The microwave energy produced by the magnetron is channelled through the waveguide into the cavity feed- box, and then into the cavity where the food is placed to be cooked.

5.Upon completion of the cooking time, the power transformer, oven lamp, etc. are turned off, and the generation of microwave energy is stopped. The oven will revert to the OFF condition.

6.When the door is opened during a cook cycle, the monitor switch, secondary switch, door sensing switch, primary switch and secondary interlock relay are activated with the following results. The circuits to the turntable motor, the cooling fan motor, and the high voltage components are de-energized, the oven lamp remains on, and the digital read-out displays the time still remaining in the cook cycle when the door was opened.

7.The monitor switch electrically monitors the operation of

the primary switch and primary and is mechanically associated with the door so that it will function in the following sequence.

1)When the door opens from the closed position, the primary switch, secondary switch, door sensing switch, and secondary interlock relay open their contacts and the monitor switch contacts close.

(2)When the door is closed from the open position, the monitor switch contacts open first. Then the contacts of the primary switch and door secondary switch close.

If the primary switch and the secondary switch primary contacts are closed when the door is opened, the monitor switch contacts form a short circuit through the monitor fuse, primary switch and secondary switch causing the monitor fuse to blow.

POWER LEVEL P-0 TO P-90 COOKING

When Variable Cooking Power is programmed, the 120 volts A.C. is supplied to the power transformer intermittently through the contacts of relay (RY-2) which is operated by the control unit within a 32 second time base. Microwave power operation is as follows:

VARI-MODE

ON TIME

OFF TIME

Power 10(P-HI)

32 sec.

0 sec.

(100% power)

 

 

Power 9(P-90)

30 sec.

2 sec.

(approx. 90% power)

 

 

Power 8(P-80)

26 sec.

6 sec.

(approx. 80% power)

 

 

Power 7(P-70)

24 sec.

8 sec.

(approx. 70% power)

 

 

Power 6(P-60)

22 sec.

10 sec.

(approx. 60% power)

 

 

Power 5(P-50)

18 sec.

14 sec.

(approx. 50% power)

 

 

Power 4(P-40)

16 sec.

16 sec.

(approx. 40% power)

 

 

Power 3(P-30)

12 sec.

20 sec.

(approx. 30% power)

 

 

Power 2(P-20)

8 sec.

24 sec.

(approx. 20% power)

 

 

Power 1(P-10)

6 sec.

26 sec.

(approx. 10% power)

 

 

Power 0(P-0)

0 sec.

32 sec.

(0% power)

 

 

Note: The ON/OFF time ratio does not correspond with the percentage of microwave power, because approx. 2 seconds are needed for heating of the magnetron filament.

8

Page 10
Image 10
Viking CDMOS200, CVMOS200 service manual Operation, Description of Operating Sequence, OFF Condition, Cooking Condition

CVMOS200, CDMOS200, DMOS200, VMOS200 specifications

The Viking VMOS200, DMOS200, CDMOS200, and CVMOS200 are advanced products designed for telecommunications and power management applications. Each model showcases unique features and technologies that make them stand out in their respective fields.

The VMOS200 is built on the vertical MOSFET technology, allowing for optimized performance in high-power applications. This device excels in switching capabilities and minimizing conduction losses, leading to improved efficiency. The VMOS200 is ideal for use in power amplifiers and high-frequency applications, where reliable performance and thermal stability are crucial. Its rugged design ensures that it can withstand harsh environments, making it a preferred choice for industrial and aerospace applications.

Next, the DMOS200 employs a double-diffused MOSFET technology, which enhances its thermal performance and power handling capabilities. This model is particularly effective in low-voltage applications where efficiency is paramount. The DMOS200 features a low on-resistance characteristic, allowing for reduced energy loss during operation. Its fast switching speed enables high-frequency operation, making it suitable for RF amplifiers and motor drives.

The CDMOS200 introduces a charge-balanced design, optimizing the allocation of charge carriers within the device to minimize heat generation and improve efficiency. This model is tailored for demanding applications in communications where signal integrity and power efficiency are critical. With its high breakdown voltage and robust construction, the CDMOS200 can handle more demanding operational conditions, making it popular in cellular and satellite communication systems.

Lastly, the CVMOS200 combines the advantages of vertical and charge-balanced technologies, offering a versatile solution for a broad range of applications. This hybrid design provides high efficiency, exceptional reliability, and enhanced thermal management. The CVMOS200 is particularly well-suited for switching power supplies and audio amplification. Its compact footprint allows for integration into space-constrained designs while maintaining high performance.

In summary, the Viking series of devices—VMOS200, DMOS200, CDMOS200, and CVMOS200—offer a range of features, technologies, and characteristics tailored to meet the demands of modern power electronics and telecommunications. With their robust designs, high efficiency, and adaptability to various applications, these devices are integral components for engineers and designers looking to create cutting-edge technological solutions.