Vivotek FD7141(V) manual Group: ipfilter, Users Manual

Models: FD7141(V)

1 132
Download 132 pages 1.02 Kb
Page 102
Image 102
Group: ipfilter

VIVOTEK - A Leading Provider of Multimedia Communication Solutions

Group: ipfilter

 

NAME

 

 

VALUE

 

 

SECURITY

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

enable

 

 

<boolean>

6/6

 

 

Enable or disable ipfilter settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

admin_enable

 

 

<boolean>

6/6

 

Enable or disable the function always allow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the admin IP address to access this device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

admin_ip

 

1.0.0.0 ~

 

 

6/6

 

 

Always allow this IP connect to camera when

 

 

 

 

255.255.255.255

 

 

 

 

 

 

 

admin_enable=1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

maxconnection

 

0~10

 

 

 

 

6/6

 

 

Maximum number of concurrent streaming

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection(s) limit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

allow_i<0~9>_start

 

1.0.0.0 ~

 

 

6/6

 

 

Allowed starting IP address for RTSP

 

 

 

 

255.255.255.255

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

allow_i<0~9>_end

 

1.0.0.0 ~

 

 

6/6

 

 

Allowed ending IP address for RTSP

 

 

 

 

255.255.255.255

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

deny_i<0~9>_start

 

1.0.0.0 ~

 

 

6/6

 

 

Denied starting IP address for RTSP

 

 

 

 

255.255.255.255

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

deny_i<0~9>_end

 

1.0.0.0 ~

 

 

6/6

 

 

Denied ending IP address for RTSP connection

 

 

 

 

255.255.255.255

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ipv6_allow_i<0~9>

 

1.0.0.0 ~

 

 

6/6

 

 

Allowed starting ipv6 IP address for RTSP

 

 

_start

 

255.255.255.255

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ipv6_allow_i<0~9>

 

1.0.0.0 ~

 

 

6/6

 

 

Allowed ending ipv6 IP address for RTSP

 

 

_end

 

255.255.255.255

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ipv6_deny_i<0~9>_

 

1.0.0.0 ~

 

 

6/6

 

 

Denied starting ipv6 IP address for RTSP

 

 

start

 

255.255.255.255

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ipv6_deny_i<0~9>_

 

1.0.0.0 ~

 

 

6/6

 

 

Denied ending ipv6 IP address for RTSP

 

 

end

 

255.255.255.255

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group: videoin_c<0~(n-1)>for n channel products, m is stream number, k is profile number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NAME

 

 

 

 

 

VALUE

 

 

 

SECURITY

 

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cmosfreq

 

50, 60

 

 

4/4

 

 

 

 

CMOS frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(videoin.type=2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(product dependent)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

whitebalance

 

 

 

 

 

<product

 

4/4

 

 

 

 

auto, auto white balance

 

 

 

 

 

 

 

 

dependent

 

 

 

 

 

 

 

 

manual

 

 

 

 

>

 

 

 

 

 

 

 

 

 

indoor, 3200K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fluorescent, 5500K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

outdoor, > 5500K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

102 - User's Manual