Vivotek FD7141(V) manual Query status of the digital output, Method: GET/POST, Users Manual

Models: FD7141(V)

1 132
Download 132 pages 1.02 Kb
Page 122
Image 122
http://myserver/cgi-bin/dido/getdi.cgi?di0

VIVOTEK - A Leading Provider of Multimedia Communication Solutions

http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]

If no parameter is specified, all the status of digital input will be returned.

Return:

HTTP/1.0 200 OK\r\n Content-Type: text/plain\r\n Content-Length: <length>\r\n \r\n

[di0=<state>]\r\n [di1=<state>]\r\n [di2=<state>]\r\n [di3=<state>]\r\n

where <state> can be 0 or 1.

Example: Query the status of digital input 1

Request:

http://myserver/cgi-bin/dido/getdi.cgi?di0

Response:

HTTP/1.0 200 OK\r\n

Content-Type: text/plain\r\n

Content-Length: 7\r\n

\r\n

di0=1\r\n

Query status of the digital output

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/getdo.cgi?[do0][&do1][&do2][&do3]

If no parameter is specified, all the status of digital output will be returned.

Return:

HTTP/1.0 200 OK\r\n

122 - User's Manual

Page 122
Image 122
Vivotek FD7141(V) manual Query status of the digital output, Method: GET/POST, Users Manual