Vivotek FD7141(V) Drive the digital output, Query status of the digital input, Method: GET/POST

Models: FD7141(V)

1 132
Download 132 pages 1.02 Kb
Page 121
Image 121
Drive the digital output

VIVOTEK - A Leading Provider of Multimedia Communication Solutions

localityname

string[128]

6/6

the locality name in certificate information

 

 

 

 

organizationname

string[64]

6/6

organization naem in certificate information

 

 

 

 

unit

string[32]

6/6

organizational unit name in certificate

 

 

 

information

 

 

 

 

commonname

string[64]

6/6

common name in certificate information

 

 

 

 

validdays

0 ~ 9999

6/6

certificatation valid period

 

 

 

 

Drive the digital output

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/setdo.cgi?do0=<state>[&do1=<state>][&do2=<state>] [&do3=<state>][&return=<return page>]

Where state is 0, 1. “0” means inactive or normal state while “1” means active or triggered state.

PARAMETER

 

VALUE

 

DESCRIPTION

 

 

 

 

 

 

 

 

do<num>

 

0, 1

 

0

– inactive, normal state

 

 

 

 

 

 

 

 

 

 

1

– active, triggered state

 

 

 

 

 

return

 

<return page>

 

Redirect to the page <return page> after the parameter is

 

 

 

 

assigned. The <return page> can be a full URL path or relative

 

 

 

 

path according the current path. If you omit this parameter, it

 

 

 

 

will redirect to an empty page.

 

 

 

 

 

 

 

Example: Drive the digital output 1 to triggered state and redirect to an empty page

http://myserver/cgi-bin/dido/setdo.cgi?do0=1

Query status of the digital input

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

User's Manual - 121

Page 121
Image 121
Vivotek FD7141(V) manual Drive the digital output, Query status of the digital input, Method: GET/POST, do<num>, return