patrolseq

string[120]

<blank>

1/4

 

The patrol sequence of ePTZ. All the

 

 

 

 

 

 

 

patrol position indexes will be

 

 

 

 

 

 

 

separated by ","

 

 

 

 

 

 

 

 

 

 

patroldwelling

string[160]

<blank>

1/4

 

The dwelling time (unit: second) of

 

 

 

 

 

 

 

each patrol point, separated by “,”.

 

 

 

 

 

 

 

 

 

 

preset_i<0~19>_name

string[40]

<blank>

1/7

 

Name of ePTZ preset.

 

 

 

 

 

 

 

(It should be set by ePreset.cgi rather

 

 

 

 

 

 

 

than by setparam.cgi.)

 

 

 

 

 

 

 

 

 

 

preset_i<0~19>_pos

<coordinate>

<blank>

1/7

 

Left-top corner coordinate of the

 

 

 

 

 

 

 

preset.

 

 

 

 

 

 

 

(It should be set by ePreset.cgi rather

 

 

 

 

 

 

 

than by setparam.cgi.)

 

 

 

 

 

 

 

 

 

 

preset_i<0~19>_size

<window size>

<blank>

1/7

 

Width and height of the preset.

 

 

 

 

 

 

 

(It should be set by ePreset.cgi rather

 

 

 

 

 

 

 

than by setparam.cgi.)

 

 

 

 

 

 

 

 

 

7.33 Exposure window setting per channel

Group: exposurewin_c<0~(n-1)>for n channel products

 

NAME

 

 

VALUE

 

 

DEFAULT

 

 

SECURITY

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

mode

 

 

auto, custom,

 

 

auto

 

4/4

 

 

The mode indicates

 

 

 

 

 

blc

 

 

 

 

 

 

 

 

how to decide the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exposure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

auto: Use full view

 

 

 

 

 

 

 

 

 

 

 

 

 

 

as the only one

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exposure window.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

custom: Use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

inclusive and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exclusive window.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

blc: Use BLC.

 

 

win_i<0~9>_enable

 

<boolean>

 

0

 

4/4

 

Enable or disable the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

window.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

win_i<0~9>_policy

 

0~1

 

0

 

4/4

 

 

0: Indicate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exclusive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1: Indicate inclusive.

 

 

win_i<0~9>_home

 

<coordinate>

 

110,90

 

4/4

 

 

Left-top corner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

coordinate of the

 

180 - User's Manual