VIVOTEK

URL Command Document for All SeriesFD8164

7.32 ePTZ setting

Group: eptz_c<0~(n-1)>for n channel product.

PARAMETER

 

VALUE

 

DEFAULT

 

SECURITY

 

DESCRIPTION

 

 

 

 

 

 

 

(get/set)

 

 

 

osdzoom

 

<boolean>

 

1

 

1/4

 

Indicates multiple of zoom in is

 

 

 

 

 

 

 

 

 

“on-screen display” or not

 

 

 

 

 

 

 

 

 

 

 

smooth

 

<boolean>

 

1

 

1/4

 

Enable the ePTZ "move smoothly"

 

 

 

 

 

 

 

 

 

feature

 

 

 

 

 

 

 

 

 

 

 

tiltspeed

 

-5 ~ 5

 

0

 

1/7

 

Tilt speed

 

 

 

 

 

 

 

 

 

(It should be set by eCamCtrl.cgi

 

 

 

 

 

 

 

 

 

rather than by setparam.cgi.)

 

 

 

 

 

 

 

 

 

 

 

panspeed

 

-5 ~ 5

 

0

 

1/7

 

Pan speed

 

 

 

 

 

 

 

 

 

(It should be set by eCamCtrl.cgi

 

 

 

 

 

 

 

 

 

rather than by setparam.cgi.)

 

 

 

 

 

 

 

 

 

 

 

zoomspeed

 

-5 ~ 5

 

0

 

1/7

 

Zoom speed

 

 

 

 

 

 

 

 

 

(It should be set by eCamCtrl.cgi

 

 

 

 

 

 

 

 

 

rather than by setparam.cgi.)

 

 

 

 

 

 

 

 

 

 

 

autospeed

 

1 ~ 5

 

1

 

1/7

 

Auto pan/patrol speed

 

 

 

 

 

 

 

 

 

(It should be set by eCamCtrl.cgi

 

 

 

 

 

 

 

 

 

rather than by setparam.cgi.)

 

 

 

 

 

 

 

 

 

 

 

Group: eptz_c<0~(n-1)>_s<0~(m-1)>for n channel product and m is the number of streams which support ePTZ.

PARAMETER

 

VALUE

 

DEFAULT

 

SECURITY

 

DESCRIPTION

 

 

 

 

 

 

 

(get/set)

 

 

 

patrolseq

 

string[120]

 

<blank>

 

1/4

 

The patrol sequence of ePTZ. All the

 

 

 

 

 

 

 

 

 

patrol position indexes will be

 

 

 

 

 

 

 

 

 

separated by ","

 

 

 

 

 

 

 

 

 

 

 

patroldwelling

 

string[160]

 

<blank>

 

1/4

 

The dwelling time (unit: second) of

 

 

 

 

 

 

 

 

 

each patrol point, separated by “,”.

 

 

 

 

 

 

 

 

 

 

 

preset_i<0~19>_name

 

string[40]

 

<blank>

 

1/7

 

Name of ePTZ preset.

 

 

 

 

 

 

 

 

 

(It should be set by ePreset.cgi rather

 

 

 

 

 

 

 

 

 

than by setparam.cgi.)

 

 

 

 

 

 

 

 

 

 

 

preset_i<0~19>_pos

 

<coordinate>

 

<blank>

 

1/7

 

Left-top corner coordinate of the

 

 

 

 

 

 

 

 

 

preset.

 

 

 

 

 

 

 

 

 

(It should be set by ePreset.cgi rather

 

 

 

 

 

 

 

 

 

than by setparam.cgi.)

 

 

 

 

 

 

 

 

 

 

 

57

User's Manual - 173

 

 

Page 173
Image 173
Vivotek FD8164 user manual EPTZ setting, Group eptzc0~n-1for n channel product