Vivotek FD8361 user manual Open the Network Stream, Senddata capability.nuart0

Models: FD8361

1 159
Download 159 pages 46.27 Kb
Page 153
Image 153

VIVOTEK

Syntax:

http://<servername>/<network_rtsp_s<0~m-1>_accessname>

“m” is the stream number.

“network_accessname_<0~(m-1)>” is the accessname for stream “1” to stream “m”. Please refer to the “subgroup of network: rtsp” for setting the accessname of SDP.

You can get the SDP by HTTP GET.

Open the Network Stream

Note: This request requires Viewer access privileges.

Syntax:

For HTTP push server (MJPEG):

http://<servername>/<network_http_s<0~m-1>_accessname>

For RTSP (MP4), the user needs to input the URL below into an RTSP compatible player.

rtsp://<servername>/<network_rtsp_s<0~m-1>_accessname>

“m” is the stream number.

For details on streaming protocol, please refer to the “control signaling” and “data format” documents.

Senddata (capability.nuart>0)

Note: This request requires Viewer privileges.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/viewer/senddata.cgi? [com=<value>][&data=<value>][&flush=<value>] [&wait=<value>] [&read=<value>]

PARAMETER

 

VALUE

 

DESCRIPTION

 

com

 

1 ~ <max. com port

 

The target COM/RS485 port number.

 

 

 

number>

 

 

 

 

 

 

 

 

 

data

 

<hex decimal data>[,<hex

 

The <hex decimal data> is a series of digits from 0 ~ 9, A ~ F.

 

 

 

decimal data>]

 

Each comma separates the commands by 200 milliseconds.

 

 

 

 

 

 

 

flush

 

yes,no

 

yes: Receive data buffer of the COM port will be cleared before

 

 

 

 

 

read.

 

 

 

 

 

 

 

User's Manual - 153

Page 153
Image 153
Vivotek FD8361 user manual Open the Network Stream, Senddata capability.nuart0