Vivotek IP7130 manual Drive the Digital Output, Query Status of the Digital Input, Method GET/POST

Models: IP7130

1 125
Download 125 pages 9.48 Kb
Page 115
Image 115
Drive the Digital Output

VIVOTEK - A Leading Provider of Multimedia Communication Solutions

unit

string[32]

6/6

Organizational unit name in the certificate

 

 

 

information.

 

 

 

 

commonname

string[64]

6/6

Common name in the certificate information.

 

 

 

 

validdays

0 ~ 9999

6/6

Valid period for the certification.

 

 

 

 

Drive the Digital Output

Note: This request requires Viewer privileges.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>] [&do3=<state>][&do4=<state>][&return=<return page>]

Where state is 0 or 1; “0” means inactive or normal state, while “1” means active or triggered state.

PARAMETER

 

VALUE

 

DESCRIPTION

 

 

 

 

 

 

 

 

do<num>

 

0, 1

 

0

– Inactive, normal state

 

 

 

 

 

 

 

 

 

 

1

– Active, triggered state

 

 

 

 

 

return

 

<return page>

 

Redirect to the page <return page> after the parameter is

 

 

 

 

assigned. The <return page> can be a full URL path or relative

 

 

 

 

path according to the current path. If you omit this parameter, it

 

 

 

 

will redirect to an empty page.

 

 

 

 

 

 

 

Example: Drive the digital output 1 to triggered state and redirect to an empty page.

http://myserver/cgi-bin/dido/setdo.cgi?do1=1

Query Status of the Digital Input

Note: This request requires Viewer privileges.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]

If no parameter is specified, all of the digital input statuses will be returned.

User's Manual - 115