Set Temperature Activation Threshold (TWRFS-I models only)

Set Temperature Activation Threshold (TWRFS-I models only)

The freeze sensor temperature activation threshold is adjustable from 2°C to 7°C ( 35°F to 45°F). When the air temperature reaches the threshold setting, the freeze sensor activates the receiver, and the Select Centigrade or Fahrenheit Temperature Scale Freeze Status indicator will turn on. The sensor system will return to the Monitor mode when the outside air temperature rises above the sensor threshold temperature.

Select Centigrade or Fahrenheit Temperature Scale

1.Press the Select Temperature Threshold Setup button to display the current temperature scale (°C or °F) and the Manual backgroundManual backgroundManual backgroundManual background Setup icon will begin flashing to indicate the selected feature can be adjusted. See Figure 16.

2.To select the alternate temperature scale, press the Manual background Advance button.

Figure 16

Select Temperature Threshold

Figure 17

1.

Press the

 

Setup button to display Temperature icon. The display

 

will indicate the current temperature threshold setting and the

Setup

 

icon will begin flashing to indicate the selected feature can be adjusted.

 

See Figure 17.

 

2.

Press the

Advance button to set the sensor threshold temperature.

Congratulations! Your Wireless Rain Sensor system installation is complete. To take advantage of the unique Water Conservation feature, review the information on the next page to select the conservation level that best suits your landscape irrigation needs.