Set Temperature Activation Threshold (TWRFS-I models only)
The freeze sensor temperature activation threshold is adjustable from 2°C to 7°C ( 35°F to 45°F). When the air temperature reaches the threshold setting, the freeze sensor activates the receiver, and the Freeze Status indicator will turn on. The sensor system will return to the Monitor mode when the outside air temperature rises above the sensor threshold temperature.
Select Centigrade or Fahrenheit Temperature Scale
1.Press the Setup button to display the current temperature scale (°C or °F) and the Setup icon will begin flashing to indicate the selected feature can be adjusted. See Figure 16.
2.To select the alternate temperature scale, press the Advance button.
Figure 16 |
Select Temperature Threshold | Figure 17 | ||
1. | Press the |
| |
Setup button to display Temperature icon. The display | |||
| will indicate the current temperature threshold setting and the | Setup | |
| icon will begin flashing to indicate the selected feature can be adjusted. | ||
| See Figure 17. |
| |
2. | Press the | Advance button to set the sensor threshold temperature. |
Congratulations! Your Wireless Rain Sensor system installation is complete. To take advantage of the unique Water Conservation feature, review the information on the next page to select the conservation level that best suits your landscape irrigation needs.
14