Troubleshooting

Troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION

Unit fails to heat up. Red Power

Unit is not plugged in.

Plug power cord into electrical outlet.

Indicator Light DOES NOT

 

 

 

 

Unit’s main power is not on.

Press On/Off Switch until it clicks.

illuminate.

 

 

 

 

Household circuit breaker / ground

Reset circuit breaker / ground fault

 

 

fault interrupter has tripped or blown

interrupter, or replace fuse. For

 

 

a fuse.

assistance, contact a licensed electrician.

 

 

Unit is damaged or otherwise in

Immediately cease usage and unplug.

 

 

need of repair.

Contact Consumer Service for

 

 

 

assistance (see Page 13 for details).

Unit fails to heat up. Red Power

No water in Boiler.

Refer to Adding Water procedure

Indicator Light DOES illuminate;

 

on Page 8 to fill Boiler.

green Heating Indicator Light DOES

 

 

NOT illuminate.

 

 

Unit heats up, but fails to steam. Both

Mineral build-up in unit.

Refer to Mineral Build-upsection on

red Power Indicator Light and

 

Page 11 for cleaning procedure.

green Heating Indicator Light DO

 

 

Unit is damaged or otherwise in

Immediately cease usage and unplug.

illuminate.

need of repair.

Contact Consumer Service for

NOTE: Always allow sufficient

 

assistance (see Page 13 for details).

time for unit to heat up and begin

 

 

producing steam.

 

 

Steam output is weak or intermittent.

Water level in Boiler is running low.

Refer to Refilling procedure on

 

 

 

Page 8 to refill Boiler.

 

 

Mineral build-up in unit.

Refer to Mineral Build-upsection on

 

 

 

Page 11 for cleaning procedure.

Excessive moisture left on floor

Microfiber Pad has become

Remove pad and replace with a

during mopping.

saturated with moisture.

fresh dry one. To purchase

NOTE: It is normal for some

 

additional Pads, contact Consumer

 

Service (see Page 14 for details).

amount of moisture to be left

 

 

behind. Allow floor some time to

Boiler has been overfilled.

Filling Boiler with more than 10 oz.

air-dry once mopping is complete.

 

(300 ml.) of water interferes with

 

 

 

steam production, resulting in water

 

 

 

condensation in steam.

 

 

 

Drain some water out of Boiler.

 

 

 

Always use included Measuring Cup

 

 

 

to fill Boiler with correct amount of

 

 

 

water (see Page 8 for details).

Floor surfaces appear cloudy or

Microfiber Pad is dirty / oversaturated.

Replace pad with a clean dry one.

streaky after steaming.

 

 

Hard water residue on floor.

Switch to distilled water.

 

 

 

 

 

 