Pelco C1621M-E (9/08) 3 manual Troubleshooting, NVR5100, Power Supply, Problem, Possible Causes

Models: C1621M-E (9/08) 3

1 40
Download 40 pages 54.2 Kb
Page 28
Image 28
Troubleshooting

Troubleshooting

If the following instructions fail to solve your problem, contact Pelco’s Product Support at 1-800-289-9100 (USA and Canada) or 1-559-292-1981 (international) for assistance.

Access the properties dialog boxes for the NVR5100 on the Endura workstation; refer to the Endura WS5000 Advanced System Software Operation manual (C1624M). Then note the following items before contacting Pelco:

Unit serial number: Located in the Properties window and on the product label

Software version: Located in the Advanced Properties dialog box

NOTE: Do not try to repair the unit yourself. Opening it immediately voids any warranty. Leave maintenance and repairs to qualified technical personnel. Exchange the defective unit and return it for repair.

NVR5100

Problem

Possible Causes

Suggested Remedy

Unit not ready.

Power turned off.

Check that the power indicator is lit.

 

 

 

 

Faulty cable connections.

Check all leads, plugs, contacts, and connections.

 

 

 

 

Defective encoder.

Check camera on a different encoder.

 

 

 

 

Network connectivity issues.

Contact your network administrator.

 

 

 

 

Drive carriers not installed properly

Shut down the NVR5100. Verify that all drive carriers are

 

or not installed in correct order.

installed correctly and in their correct drive bay slots

 

 

(1 to 12).

 

 

 

The unit is not ready for operation

Voltage failure during programming

Replace the NVR5100 and have it checked by Pelco.

after firmware upload.

of update file.

 

 

 

 

Unit status indicator is red.

Unit fan failure.

Replace the NVR5100 and have it checked by Pelco.

 

 

 

 

Power supply output voltage

Check power supply and line voltage.

 

fluctuates more than 8 percent.

 

 

 

 

Unit status indicator is red and

Power loss to either power supply.

Check each power supply, line voltage, and the UPS.

the power supply alarm sounds.

 

 

Power supply module failure.

Replace failed power supply.

 

 

 

Unit status and hard drive

Hard drive failure.

Replace failed hard drive.

indicators are red and the unit

 

 

alarm sounds.

 

 

 

 

 

The unit status indicator continues to glow red after you correct the problem. It can be cleared from Endura workstations and VCD5000 video console displays.

POWER SUPPLY

The primary and secondary power supplies are both equipped with status indicators. Table D describes the status by color and indicator.

Power Supply Status

Power Supply Indicator

Front Panel Status Indicator

Power Supply Audible Alarm

 

 

 

 

Normal

Solid Green

Solid Green

Silent

 

 

 

 

Power problem

Solid Red

Solid Red

Alarm Sounds

 

 

 

 

Power supply failure

Dark

Solid Red

Silent

 

 

 

 

Replace the appropriate power supply if there is any problem (refer to Appendix C: Replacing a Power Supply on page 35).