RACK MOUNTING
The NVR5100 mounts into an
The rack must meet the following requirements:
•
•Rack column depth: 24 to 30 inches (61 to 76 cm)
•Column mounting hole provisions:
•Door systems are acceptable. Front doors must have at least 2 inches (5.1 cm) between the NVR5100 front bezel and the inside of the door. Rear doors may only be used on rack columns that are more than 26 inches (66 cm) deep.
WARNINGS:
•Secure the front and rear screws to the support rails.
•Make sure the NVR5100 is level.
•Slots and openings in the cabinet provide ventilation to prevent the unit from overheating. Do not block these openings. Never place the unit near or over a radiator or heat register. When placing the unit in a rack, be sure to provide proper ventilation.
To install the NVR5100 in a rack:
NOTE: Figure 4 identifies each piece of hardware for this procedure.
1.If chassis mounting brackets are not attached: Attach one mounting bracket to each side of the NVR5100. Use six
ATTACH BRACKETS
(6) SCREWS
Figure 9. Fastening Mounting Brackets to Chassis