ECONOLINE SERVICE AND PARTS
THERMOSTAT (BJWA)
To Adjust By-Pass Flame (Minimum Burner Flame):
When oven reaches the temperature at which the dial is set, the oven control cuts down the flow of gas to the amount required to keep the oven at that temperature. The control must
1.Light oven burner, then turn dial to highest set tem- perature.
2.After 5 minutes, turn dial clockwise to a point slightly beyond first mark on dial (shown by "X").
3.Remove dial and sleeve.
4.With a screwdriver, turn
5.Replace sleeve and dial, turning dial clockwise until it locks in the OFF position.
Fig. 5
– 7 –