SCHEMATIC
M
V
W | R |
|
H | E | THERMOSTAT |
T | D | |
| 1 | 2 |
|
| 3 |
LIMIT
4
COMPONENT FUNCTION
Thermostat - Millivolt type with capillary bulb,
Thermopile - Millivolt control with 24" capillary. Rated to generate 500 millivolts.
Combination Valve - Regulates gas flow to burner and pilot. Provides pilot safety.
– 14 –