Vulcan-Hart EF5 ML-114944, EF4 ML-114943, EF3 ML-52099 service manual High Limit

Models: EF3 ML-52099 EF4 ML-114943 EF5 ML-114944

1 16
Download 16 pages 62.77 Kb
Page 6
Image 6
HIGH LIMIT

7. Loosen the packing nut and holding nut.

8. Remove the thermostat bulb from the clamp.

9.Pull the thermostat bulb through the underside of the fry tank and remove the thermostat assembly.

10.Reverse the procedure to install. When installing the new thermostat assembly, do not kink the thermostat capillary. Wrap threads of packing nut with Teflon tape to prevent leakage.

HIGH LIMIT

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

1.Drain shortening from fry tank.

2.Remove heat shield as outlined under Covers and Panels.

3.Remove wire leads from high limit, noting all connections for reassembly.

4.Remove high limit from mounting bracket.

5.Remove left burner as outlined under Burners.

– 6 –

Page 6
Image 6
Vulcan-Hart EF5 ML-114944, EF4 ML-114943, EF3 ML-52099 service manual High Limit