Vulcan-Hart EF5 ML-114944, EF4 ML-114943, EF3 ML-52099 service manual General

Models: EF3 ML-52099 EF4 ML-114943 EF5 ML-114944

1 16
Download 16 pages 62.77 Kb
Page 3
Image 3
GENERAL

GENERAL

INTRODUCTION

Models

This service manual was written for:

EF3, EF4 and EF5 Gas Fryers.

INSTALLATION

Generally, installations are made by the dealer or contracted by the dealer or owner. Detailed installation instructions are included in the Installation and Operation Manual, which is sent with each fryer.

OIL FILTERING

Filtering instructions are included in the Installation and Operation Manual.

NOTE: If pilot does not remain lit, repeat steps 2 through 5, but allow a longer period of time before releasing the combination valve knob. Adjust pilot flame, if necessary, as outlined under Pilot Adjustment in Service Procedures and Adjustments.

6. Turn combination valve knob to ON.

SPECIFICATIONS

Gas Data

Model

No. Tubes

BTU/HR

 

 

 

EF3

3

90,000

 

 

 

EF4

4

120,000

 

 

 

EF5

5

150,000

 

 

 

OPERATION

Detailed operation instructions are included with each fryer in the Installation and Operation Manual.

CLEANING

Detailed cleaning procedures are included in the Installation and Operation Manual.

LIGHTING PILOT

1.Turn thermostat OFF.

2.Push combination valve knob in and turn to OFF.

3.Wait 5 minutes for unburned gas to vent.

4.Push combination valve knob in and turn to

PILOT.

5.While holding the combination valve knob in, light the pilot with a lit taper. Hold the combination valve knob in for approximately 30 seconds before releasing.

TOOLS

Standard

Hand tools (standard set)

VOM with AC current tester (any quality VOM with a sensitivity of at least 20,000 ohms per volt can be used)

Gas test kit

Temperature tester (thermocouple type)

Manometer

– 3 –

Page 3
Image 3