Solenoid (C Model)

WARNING: Always perform the Electrical Lockout/Tagout procedure before removing any sheet metal panels or attempting to service this equipment. Failure to comply with this procedure can cause property damage, injury or death.

WARNING: Perform the GAS LOCKOUT/TAGOUT procedure before servicing the unit.

1.Perform the SOLENOID, PILOT SAFETY AND GAS SHUT-OFF VALVE ASSEMBLY removal procedure.

2.Remove the flex line fitting from the top of the solenoid.

3.Remove the solenoid from the pipe nipple.

4.Remove any residual tape from the pipe nipples and fittings and coat the threads with new gas-rated (yellow) Teflon tape.

WARNING: All gas joints disturbed during servicing must be checked for leaks. Do not use an open flame. Use a hazardous gas tester or a soap and water solution (Bubbles indicate a gas leak). Failure to comply can cause property damage, injury or death.

5.Reverse the procedure to install the solenoid.

6.Test the oven to verify proper operation.

Figure 13: C Model Solenoid Removal

Pilot Safety Valve (C Model)

WARNING: Always perform the Electrical Lockout/Tagout procedure before removing any sheet metal panels or attempting to service this equipment. Failure to comply with this procedure can cause property damage, injury or death.

WARNING: Perform the GAS LOCKOUT/TAGOUT procedure before servicing the unit.

1.Perform the SOLENOID, PILOT SAFETY AND GAS SHUT-OFF VALVE ASSEMBLY removal procedure.

2.Remove the flex line and flex line fitting from the pilot safety valve.

3.Remove the screw, lock washer and nut securing the pilot safety valve to the gas mount bracket.