Vulcan-Hart ML-126881, ML-126883, GPC12S manual High Limit Device, Overflow/Skim Port

Models: GPC12S ML-126883 ML-126881 GPC12

1 20
Download 20 pages 29.23 Kb
Page 17
Image 17
HIGH LIMIT DEVICE

HIGH LIMIT DEVICE

If the water level goes below the thermostat and high limit location (Fig. 13), the high limit will turn the pasta cooker off and extinguish the pilot. DO NOT relight the pilot until the tank has been refilled with water.

OVERFLOW/SKIM PORT

An overflow/skim port is provided at the front of the tank (Fig. 13) and a fill port spray nozzle is provided at the right rear of the tank just above the fill line (Fig. 14).

Thermostat

High Limit

Device

Overflow / Skim

Port

FILL LINE

PL-40199-1

Fig. 13

FILL PORT SPRAY NOZZLE

PL-41474-1

Fig. 14

The overflow/skim port serves two functions:

1.Allows operator to skim foam and starch debris from the product while cooking and also while filling with fresh water.

2.Keeps the tank from overflowing during filling.

– 17 –